Figure 6
1 Limit switch for side brush 1 start
(SB1_a)
2 Limit switch for side brush 1 end
(SB1_e)
Figure 7
1 Running rollers
2 Eccentric
Figure 8
1 Stop buffer side-brush oscillate
Figure 9
1 Light barrier of drier forward
2 Light barrier of drier in the middle
3 Light barrier of drier behind
Danger
Risk of electric shock!
Work on electrical plant only to be carried
out by qualified electricians.
Switch the plant to voltage-free with all
work, in this case switch the plant at the
main switch to “0”and secure against it
switching on again.
Who may remedy faults?
Operator
Work designated with the sign “Operator”
may only be carried out by persons who
have been instructed in the safe operation
and maintenance on the wash plant
Electricians
Persons with a professional training in the
electro-technical area.
Customer Service
Work designated with the sign “Customer
Service” may only be done by the fitters of
Kärcher Customer Service or fitters who
have been authorised by Kärcher.
Danger
Risk of electric shock! Switch on the plant
voltage-free, in addition switch on the main
switch to “0” and secure against it switching
on again.
Risk of injury from compressed air unex-
pectedly emerging. . Compressed air con-
tainers also remain under pressure after the
plant has been switched off. It is absolutely
necessary to get rid of pressure before
starting work on the plant. To do this, turn
off the compressed air supply and use the
manual operation to move the wheel wash
system in and out until the pressure has
been released. Then check for the absence
of pressure on the manometer at the main-
tenance unit.
Risk of injury from high-pressure water jet
unexpectedly emerging. The high pressure
system continues to remain under pressure
also after the plant has been switched off. It
is absolutely necessary to remove all pres-
sure in the high-pressure system before
starting work on the plant.
Risk of eye injuries from parts flying off or
dirt. Keep clear off rotating brushes. Gog-
gles must be worn during maintenance
work.
1 Display
Faults recognised by the control unit are
shown in the plant display or the display on
the comfort operating point (option).
Note
Only faults that can be remedied by the op-
erator are stated in the following section. If
other faults are shown in the display, inform
the Customer Service.
Faults
Fault indication