ELDOM Green Line WV12046SRD - Инструкция по эксплуатации - Страница 12

Водонагреватели ELDOM Green Line WV12046SRD - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.

Если остались вопросы, задайте их в комментариях после инструкции.

"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.
Страница:
/ 56
Загружаем инструкцию
background image

optimum temperature at which the heat losses of the device are reduced 
and the reduced use of electric energy. At the same time, the warm water is 
sufficient for normal households. When a need for a large amount of mixed 
water  is  required  the  thermostat  knob  is  rotated  in  the  direction  of  travel 
counterclockwise to its maximum position, to reach the higher temperature 
of the water in the tank. We recommend to keep the knob in the sector ECO, 
when the heater is left on for long periods without use of hot water and only to 
store heated water. 
The  appliance  built-in  thermostat  unit  has  antifreeze  function.  When  the 
thermostat  knob  is  to  the  extreme  left,  at  the  scale  beginning,  the  heater 
shall switch on at ambient temperature around 8-10°C and shall switch off at 
about 12-15°C. Thus in case of air temperature fall in the room, the water in 
the tank will be protected from freezing. ATTENTION! This feature shall not 
prevent the water in the room plumbing from freezing!
Switching  on  and  off,  set  up  and  using  water  heaters  equipped  with 
electronic control board takes place in accordance with the instructions and 
requirements listed in the additional manual supplied with the appliance - 
instruction  how  to  connect  and  use  an  appliance  with  electronic  control 
board. For such appliances the additional instruction manual is an integral 
part of the present installation and operation manual.
The 

temperature  indicator

  installed  on  the  appliance  external  coating 

indicates  the  process  of  water  heating. 

I

t  is  not  a  device  for  control 

measurement and indicates only the approximate temperature and quantity 
of hot water within the water tank.

WARNING!

 Do never switch the appliance if there is a chance that the 

water in the water tank is frozen! This shall damage both heater and the 
tank.

WARNING!

 

This appliance may be used by children of age over eight 

years  old  and  persons  with  reduced  physical,  sensory  or  mental 
capabilities, or lack of experience and knowledge, where they are under 
supervision  or  instructed  about  the  safe  use  of  the  appliance  and 
understand the dangers. Children must not be allowed to play with the 
unit!  It  is  absolutely  forbidden  that  children  undertake  cleaning  or 
servicing of this appliance!

Within the combined valve is built a special 

valve

 which during water heater 

normal  operation  allows  the  expanded  during  heating  water  not  to  leak 
through  the  valve  side  hole,  but  to  pass  into  cold  water  plumbing.  The 
quantity  of  this  water  is  negligible  and  usually  is  with  low  temperature. 
During  normal  operation  of  the  water  heater,  as  well  as  in  present  of 
additional return valve, it is possible that through the valve side opening leak 
some water drops. This should not be perceived as defect and the side hole 
of combined valve should not be blocked because it shall cause destruction 
of the tank. The built-in non-return valve in the

 combined

 valve prevents, in 

case  of  cutting  water  supply,  the  water  in  the  water  tank  to  return  to  cold 
water pipeline.
Using the built-in heater exchangers (for appliances equipped with) to heat 
the  water  in  the  tank  must  take  place  in  accordance  with  the  instruction 
provided for by the persons who carried out the design and installation of the 
system for heating water from alternative electric sources. Compliance with 
the instruction in such guides is mandatory.
When the appliance is used in areas with water rich in limestone it is possible 
to hear some noises during water heating. The noise is due to the limestone 

deposition

 on the heater and 

in

 the tank. The quantity of limestone contained 

depends of the type of water and its heating temperature. When the latter is 
higher  than  60°С  the  quantity  of  separate  limestone  increases. 
Accumulated limestone impedes the heater efficiency and may even cause 
its failure, while increasing the time for water heating.
When using the appliance it is possible to hear some weak noise due to the 
water flow through the pipelines and the appliance, as well as to the natural 
process of expanding and heating.
When the heater is regularly used to heat water to a lower temperature, it is 
recommended  to  turn  the  thermostat  knob  at  least  once  monthly  to  its 
maximum position, then to heat the water to maximum degrees and keep it 
such at least for 24 hours. The purpose it to prevent bacteria growth.

ADDITIONAL CORROSION PROTECTION

Enameled water heater tanks. 

In each water heater with enameled tank is 

installed additional corrosion protection. It consists of an anode of special 

alloy operating only when the water tank is full. The anode is a consumable 
(i.e.  a  device  with  normal  wear  during  the  appliance  operation)  and  its 
average operational life is up to 

3

 (

three

) years. This period depends much 

of the type of operating the appliance and the characteristics of the heated 
water.  After  the  period  of  operational  life,  a  manufacturer  authorized 
specialist  or  dealer  service  company  must  check  the  conditions  of  the 
anode. Where necessary it should be replaced with new one. Compliance 
with  the  inspection  deadline  and  timely  replacement  of  the  anode  is 
important  for  the  effective  protection  of  the  tank  from  corrosion.  Both  the 
assessment and replacement of the anode are not subject of manufacturer 
and seller warranty liabilities.

Water heater with enamel tank and anode tester.

 The availability of the 

anode tester as control device is essential for the heater operation. Some 
water  heater  modifications  with  traditional  thermostat  are  equipped  with 
electromechanical  anode  tester  (Fig.  9).  It  consists  of  a  arrow-indicating 
system with a scale and switch (button). The scale has two sections - red 
and green. In tank normal operating condition the tester pointer is in the red 
section - the tester is not switched on and the anode is working properly. 
Checking the anode efficiency is carried out when the water is fully heated 
(

switched off 

 thermostat

,

 i.e. the key is not lit) by pressing for few seconds 

the button on the tester. The arrow shall depart in the direction of the scale 
green  sector.  The  magnitude  of  the  variation  is  strongly  affected  by  the 
parameters of the water and its temperature, as the boundary between the 
two sectors correspond to the water average values. The anode efficiency 
criterion  is  its  arrow  deflection.  When  at  the  time  of  pressing  the  tester 
button,  the  arrow  does  not  divert  or  is  hold  at  the  beginning  of  the  red 
section, you should contact the specialists at your nearest manufacturer or 
vendor authorized service company. Their specialist shall review the tank 
corrosion  protection  and  repair,  if  necessary.  In  some  water  heaters 
modifications the electronic control board indicates the anode efficiency and 
degree of wear with periodic regular display blinking. With advanced wear 
the size of lighted part decreases. More specifically the process is described 
in the additional instruction manual concerning the electronic control board 
functions. Once the lighted part of the display switches off completely you 
may contact the closest service company to review and eventually replace 
the anode.

Water tanks of high quality chrome-nickel steel

. Corrosion protection and 

guaranteed long life are secured by correct choice of steel, adequate design 
and engineering construction during tank manufacture process.

SERVICE, PREVENTION, MAINTENANCE

In  order  to  secure  reliable  operation  of  the  water  tank  in  areas  with  highly 
calcareous  water  it  is  recommended  to  clean  the  limestone  accumulated 
within. This operation should take place at least once every two years, while in 
areas with higher limestone content even more frequently. The depositions 
on the enamel coating should not be removed otherwise than wiped with dry 
cotton  cloth  and  without  using  hard  tools.  Regular  limestone  removal  and 
cleaning  is  particularly  important  for  appliance  reliable  operation.  It  is 
recommended that during this maintenance operation you carry out a review 
of  the  enameled  tank  anode  condition.  These  services  are  not  subject  to 
warranty coverage and must be performed only by qualified person.

WARNING!

 

In order to ensure safe and trouble-free operation of the water 

heater, the combined valve should be checked regularly for reduction of its 
permeability. This is done by lifting the lever, and wait for 30-60 seconds 
from the side opening the valve to flow thick and strong jet of water. This 
operation must be carried out after connecting the heater to the plumbing 
and when filling of the tank with water

,

 in the process of using the heater 

not less than once every two weeks, as well as eventually after stop and 
start of water supply. When at full tank by opening the valve does not leak 
or water flow is weak, there is a failure and probably the valve is clogged 
by impurities in the sewage. Using water heater combined with a defective 
valve is strictly prohibited. Switch off immediately the appliance from the 
power supply and contact the nearest authorized by manufacturer service 
company. Otherwise, it will cause damage to the water tank, and could 
cause  tangible  and  intangible  damages  in  the  room  where  the  water 
heater is located.

When you are not certain about the temperature in the room where the water 
heater is installed, i.e. that it may fall below 0°C, the water from the water 
tank  MUST  be  drained  -  please  refer  to  section  'CONNECTION TO THE 

12

EN

EN

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к ELDOM Green Line WV12046SRD?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"