Instructions for use and maintenance

       

7

EN

English

Dear Clients,

The TESY team would like to congratulate you on your new 

purchase. We hope that your new appliance shall bring 

more comfort to your home.

This technical description and instructions manual was 

prepared in order to acquaint you with the product 

and the conditions of proper installation and use. These 

instructions were also intended for use by qualified 

technicians, who shall perform the initial installation, or 

disassembly and repairs in the event of a breakdown. 

The observance of the instructions contained herein is 

in the interest of the buyer and represents one of the 

warranty conditions, outlined in the warranty card.

Please consider that following the current instructions 

will primarily be of interest to the consumer, but along 

with this, it is also one of the warranty conditions, pointed 

out in the warranty card, so that the consumer can 

benefit from the free warranty services. The producer is 

not responsible for damages in the appliance that have 

appeared as a result of operation and/or installation not 

corresponding to the instructions here.

The electric water heater complies with the requirements 

of EN 60335-1, EN 60335-2-21.

I. 

PURPOSE OF USE

The appliance is designed to supply hot water to 

household facilities equipped with a piping system 

operating with pressure not greater than 6 bars (0,6 Mpa).

It is designed to operate only in closed and heated 

premises where the temperature is not lower than 4°C and 

it is not designed to operate in a continuous protracted 

regime.  

II. 

TECHNICAL SPECIFICATIONS

1. 

Nominal volume V, liters - see the appliance's rating plate

2. 

Nominal voltage  - see the appliance's rating plate

3. 

Nominal power consumption - see the appliance's 

rating plate

4. 

Nominal pressure - see the appliance's rating plate

ATTENTION! This is not the water mains pressure. This 

is the pressure that is announced for the appliance and 

refers to the requirements of the safety standards. 

5. 

Water heater type - closed accumulating water heater, 

with thermal insulation

6. 

Inner coating: GC-glass-ceramics

7. 

Daily energy consumption – see Annex I

8. 

Rated load profile - see Annex I

9. 

Quantity of mixed water at 40°C V40 litres - see Annex I

10. 

 Maximum temperature of the thermostat - see Annex I

11. 

 Default temperature settings - see Annex I

12. 

 Energy efficiency during water heating - see Annex I

III. 

IMPORTANT RULES

 •

The water heater must only be mounted in premises with normal fire 

resistance.

 •

Do not switch on the water heater unless you established it was filled 

with water. 

Attention! Improper installation and connection of the appliance may make it 

hazardous for the health and life of consumers. It may cause grievous and 

permanent consequences, including but not limited to physical injuries and/or death. 

Improper installation and connection of the appliance may also lead to damage to 

the consumers’ property /damage and/ or destruction/, or to that of third persons, as 

a result of, but not limited to flooding, explosion and/or fire. 

Installation, connection to the main water and power supply, and putting into 

operation must be carried out by certified electricians and technical personnel 

certified in installation of this category of appliances, who have obtained their 

license in the state where the installation and commissioning of the appliance are 

carried out, and in compliance with its local legislation.

 •

Upon connecting the water heater to the electric mains care must be 

taken to connect the safety lead (for models without power cord with 

plug).

 •

If the water-heater will not be used for a longer period of time (more 

than 3 days) and the temperature in the premise could drop below  0°C, 

the water in the water-heater must be drained (observe the procedure 

outlined in subsection 2 

“Water heater's piping connection”

 of s. IV), to 

avoid any possible damage of the appliance.

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к TESY GCU 1015 L52 RC 304141?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"