50
STMiE3E ed 09/11
MINI EOLO 3 E
Technical Documentation
Technical Documentation
ERROR 03
Fan anomaly
0 3
a
There are 220 VDC on clamps 3-4 of the X7 connector on the P.C.B. No
Replace the P.C.B.
Yes
230 V DC are present on the fan terminals.
No
Restore the electric connection/replace the wiring.
Yes
Replace the fan.
0 3
b
The flue has been installed correctly.
No
Clean/restore the correct operation of the flue.
Check maximum lengths and any possible obstructions.
Yes
The silicone tube that connects the fan to the flue pressure switch
is intact/clean.
No
Restore/replace the silicone tube.
Yes
Replace the fan. If the anomaly persists, replace the P.C.B.
ERROR 04
Generic boiler P.C.B. anomaly
04
The gas valve is operating correctly.
No
Check the wiring of the electrical connection and make sure it is clean.
Yes
Replace the P.C.B. If the error continues check the quality of the power supply to exclude any external interference.
ERROR 05
Flow probe anomaly
05
The wiring between the flow probe and the board (connector X4
terminals 6-7) is OK.
No
Restore the electric connection/replace the wiring.
Yes
Replace the NTC flow probe. If the anomaly persists, replace the P.C.B.
ERROR 06
Domestic hot water probe anomaly
06
The wiring between the DHW probe and the board (connector X2
terminals 4-5) is OK.
No
Restore the electric connection/replace the wiring.
Yes
Replace DHW NTC probe. If the anomaly persists, replace the P.C.B.
ERROR 10
Insufficient system pressure
10
The boiler manometer displays a pressure exceeding 0.8 bar.
No
Restore the correct pressure by acting on the system filling valve.
N.B.: in this case it is always advisable to ensure that there are no leaks
in the central heating plant and check the correct factory-set value of the
expansion vessel.
Yes
The wiring between the absolute pressure switch and the board is OK. No
Restore the electric connection/replace the wiring.
Yes
Check/replace the system pressure switch. If the anomaly persists, replace the P.C.B.
ERROR 11
Flue pressure switch anomaly
This error occurs when the contact of the flue pressure switch is closed and the
fan is at a standstill.
11
The fan is at a standstill.
No
Check the flue and make sure the chimney draught is working fine.
N.B.: the problem may be caused by an excessive residual draught in the
chimney or by the presence of other extractors in the flue pipes.
Yes
replace the flue pressure switch. If the anomaly persists, replace the P.C.B.
Характеристики