32
INS
T
ALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
TECHNI
CAL D
A
T
A
Air conditioning
In this mode, the system works both to produce DHW and to cool the room.
The temperature of the DHW is always regulated via buttons (4), the central heating temperature is regulated via buttons (5) and the rela-
tive temperature is shown on the display by the indicator (14).
From here on, the system works automatically. If there are no requests (room central heating, DHW production or cooling), the system
goes into the “stand-by” function.
Each time the outdoor unit ignites, the display shows the corresponding symbol (8) with the corresponding power scale (10).
Air conditioning and room cooling in progress mode
24
Operation with external probe
The system is set up to use the outdoor unit external probe or an optional external probe.
With the external probe connected, the system flow temperature for room heating and air conditioning is managed by the external probe
based on the outdoor temperature measured (Parag. 1.15).
You can change the flow temperature by choosing the offset value in the specific user menu.
In this case, any settings made on the indoor unit will not affect system operation.
Dehumidify
If the system is coupled to a humidistat (optional) or a humidity temperature sensor or a remote zone panel (optional), you can manage
the room humidity in summer air conditioning mode.
– If coupled to a humidistat, set the degree of humidity on the humidistat itself (see the instruction booklet).
– If coupled to a humidity temperature sensor, set the humidity percentage in the relative user menu.
– If coupled to a zone remote panel, set the humidity percentage in the relative user menu of the control panel or directly in the menu of
the panel (see instruction booklet).
Air conditioning and Dehumidification active mode
25
In central heating or cooling request mode, if the temperature of the water in the system meets the request, the system can work
simply by activating the circulator pump.
Характеристики
Остались вопросы?Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)