30
INS
T
ALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
TECHNI
CAL D
A
T
A
At the end of its service life, the appliance must not be disposed of like normal household waste
nor abandoned in the environment, but must be removed by a professionally authorised com-
pany as required by current legislation.
Contact the manufacturer for disposal instructions.
2.2
CLEANING AND MAINTENANCE
To preserve the system's integrity and keep the safety features, performance and reliability, which distinguish the assembly,
unchanged over time, you must execute maintenance operations on a yearly basis in compliance with what is stated in the rela-
tive point at “annual check and maintenance of the appliance”, in compliance with national, regional, or local standards in
force.
2.3
CONTROL PANEL
21
Key (Fig. 21):
1
- Operating mode (winter - air conditioning - summer - stand-
by - off ) and parameter confirm button
2
- Menu selection button
3
- Reset and exit menu button
4
- Domestic hot water temperature selection buttons
5
- Heating system temperature selection buttons
6
- Indoor unit pressure gauge
7
- Remote control connection (optional)
8
- Outdoor unit in operation
9
- Not used on this model
10
- Dispensed output level
11
- Operation with external temperature probe active (optional)
12
- Connection to other Immergas units
13
- Central heating room mode function active
14
- Temperature indicator, indoor unit info and error codes
15
- Room cooling mode operation active
16
- Operation in cooling mode
17
- Operation in winter mode
18
- Operation in summer mode
19 -
Stand-by
Mode
20
- Not used on this model
21
- Blocked indoor unit, it needs to be unblocked by pressing the
“RESET” button
22
- Operation in dehumidification mode
23
- DHW production phase operating mode active
2.4 SYSTEM USE
Before ignition, make sure the system is full of water, checking that the pressure gauge needle (6) points to a value between 1 and
1.2 bar and make sure that the chiller circuit has been filled as described in the outdoor unit instructions booklet.