Винные шкафы Pando PVMAP 88-49 PAL - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

INOXPAN S.L.
WINE CABINETS
Many common problems are easy to solve, avoiding a call to the technical service.
Try the following suggestions to solve the problem before calling the customer/after sales service.
PROBLEM
POSSIBLE CAUSE
SOLUTION
The unit does
not work.
•
Connect the unit.
•
Switch on the unit.
•
Reset the circuit breaker / ICP or change the
burnt-out fuse.
The unit does
not cool enough.
•
The temperature has not been correctly set.
•
Ambient
temperature
requires
a
higher
temperature setting.
•
The door is opened very frequently.
•
The door is not completely closed.
•
The door does not close hermetically.
•
The condenser is too dirty.
•
The ventilation opening is obstructed or contains
too much dust.
•
Check the temperature setting
•
Select a higher temperature.
•
Do not open the door unless strictly
necessary.
•
Close the door with care.
•
Check the door seal and clean or replace it.
•
Clean the condenser when necessary.
•
Remove obstructions and clean out the dust.
The unit turns
on and off
frequently.
•
Ambient temperature is higher than average.
•
Many bottles have just been added to the unit.
•
The door is opened very frequently.
•
The door is not completely closed.
•
The door does not close hermetically.
•
Place the appliance in a cooler location. Let
the appliance work for a time until it has
reached the selected temperature.
•
Do not open the door unless strictly
necessary.
•
Close the door with care.
•
Check the door seal and clean or replace it.
The light does
not come on.
•
The unit is not connected to the mains.
•
Circuit breaker triggered / ICP or fuse burnt out.
•
The light was switched off from the front panel.
•
Connect the unit.
•
Reset the circuit breaker / ICP or change the
burnt-out fuse.
•
Switch on the light using the front panel.
Vibrations.
•
The unit is not exactly level.
•
Level the unit using the adjustable feet.
The appliance
makes noises.
The rattling noise may come from the flow of the coolant, this is normal. At the end of each cycle,
you may hear gurgling noises made by the flow of coolant in the appliance. If there are temperature
fluctuations, contraction and expansion of internal walls may make cracking noises.
•
The unit is not exactly level
•
Level the unit using the adjustable feet.
The door does
not close
correctly.
•
The door opening side was changed and it has
not been correctly fitted.
•
The seal is dirty.
•
The shelves are incorrectly positioned.
•
The appliance is not properly levelled.
•
Check the door seal and refit correctly.
•
Clean the door seal.
•
Check the shelves and refit correctly.
•
Level the appliance with the adjustable feet.
7. TROUBLESHOOTING