IMPORTANT 

Before  using  the  space  heater,  carefully  read  all  of  the  instructions  and  follow  them  scrupulously.  The  manufacturer 
cannot be held responsible for damage to persons and/or property caused by improper use of the equipment.

 

This instruction manual is an integral part of the equipment and must therefore be stored carefully and passed on with the 
unit in the event of a change of ownership.

 

 

DESCRIPTION 

Space  heaters

 

are  designed  for  non-domestic  heating  of  medium 

and  large  ventilated  premises,  for  which  a  mobile  heating  system  is 
required in accordance with EN 1596:2008. 

 

Warning 

DO  NOT  USE  TO  HEAT  HABITABLE  AREAS  OF 
RESIDENTIAL BUILDINGS. 
REFER  TO  NATIONAL  REGULATIONS  FOR  USE  IN 
PUBLIC BUILDINGS. 

 
Space  heaters  can  be  run  on  propane  gas  (G31)  or  on  L.P.G. 

(butane  G30  and  propane  G31)  according  to  the  different  gas 
categories  indicated  on Tab.  I  and  shown  on  the  heater  identification 
plate. 

Space  heaters  are  direct-combustion  and  forced  convention  units. 

Air is heated by the thermal energy generated during combustion and 
is then conveyed to the room to be heated along with the combustion 
products:  the  room  MUST  be  suitably  ventilated  to  ensure  adequate 
air circulation.

 

Various safety devices  trip in the event of serious malfunction: 

  the  thermocouple  and  the  thermal  gas  valve  (M  and  M  DV 

models)  trip  to  close  the  gas  flow  if  the  flame  is  irregular  or  if  it 
goes out; 

  the  electronic  burner  control  unit  trips  if  the  flame  is  irregular  or 

goes  out  (type  A  models):  the  reset  button  (8)  lights  up  with  a 
steady red light; 

   the overheating thermostat LI trips when the temperature of the 

combustion chamber exceeds the safety limit; 

In  each  of  the  cases  described  above,  the  space  heater  stops 

working in lock-out condition. 

 

Warning 

ВoЮ ЦЮЬЭ КХаКвЬ ТНОЧЭТПв ЭСО МКЮЬО oП ЭСО “ЛХoМФ” КЧН 

eliminate  it  before  restarting  the  heater  (see: 

“TROUBLźSHOOTINż”).

 

TвpО  A  ЦoНОХЬ  МКЧ  ЫОЬЭКЫЭ  oЧХв  ТП  ЫОЬОЭ  ЛЮЭЭoЧ  “8”  ТЬ 

pressed (red lamp is off). 
 

Warning 

For  A  models,  the  reset  button  (8)  may  have  different 
light types:

 

  light off: unit is working normally, flame is regular. 

  fast flashing: unit is running on starting cycle. 

  slow  flashing:  unit  is  in  stand-by  status,  waiting  for 

heating request. 

  steady light: lock-out status. 

 

GENERAL ADVICE 

The  heater  must  be  installed,  set  up  and  used  in  accordance  with 

the  applicable  regulations  and  laws  relating  to  the  use  of  such 
equipment. 

Minimum distance from surrounding walls and/or ceiling: 2 m. 
 

Warning 

Do  not  use  the  heater  on  floors  made  with  flammable 
materials. 
 

 

Warning 

Use  in  basements  or  below  ground  level  is  hazardous 
because of gas stagnation. 
 
 

Make sure that: 

  The instructions in this manual are carefully followed; 

  The  heater  is  not  installed  in  an  area  where  there  is  a  high  risk 

of fire or explosions; 

  No  flammable  materials  are  stored  in  the  vicinity  of  the  heater 

(minimum distance: 3 m); 

  There  is  no  overheating  of  walls, or  ceilings made  of flammable 

materials, 

  All precautions have been taken to prevent fires; 

  The  premises  in  which  the  heater  is  installed  are  sufficiently 

ventilated  for  the  burner  requirements;  in  particular,  limits 
regarding  air  quality  in  the  room  to  be  heated  must  conform  to 
applicable  national  or  local  laws  or,  in  the  absence  of  any 
standards and/or indications, to the provisions of EN 1596:2008: 

  minimum  room  volume  must  be  measured  with  thermal 

power/volume  ratio  equal  to  100  W/m

3

.  Room  volume  must 

NEVER be less than 100 m

3

  a  minimum  ventilation  area  of  25  cm

2

  per  kW  of  thermal 

power must be provided, the minimum being 250 cm

2

, divided 

equally between the upper and lower part; 

  Nothing  is  obstructing  the  aspiration  and  expulsion  of  air; 

movement  of  air  may  be  obstructed  in  various  ways  including 
placing  covers  or  other  objects  on  the  heater  or  positioning  the 
heater too near a wall or other large object; 

  The  generator  is  placed  near  a  power  switchboard  having 

specifications that conform to those declared; 

  The unit is placed in a stable position; 

  The hot air jet is directed towards the cylinder. 

  The heater is regularly monitored during operation and checked 

before being started; 

  At  the  beginning  of  each  work  period,  a  check  is  made  that  the 

fan  moves  freely  before  plugging  the  heater  into  the  electrical 
power supply; 

  At the  end  of  each  work  period, the mains switch  is  disengaged 

and  supply  power  cord  removed,  main  gas  stopcock  is  closed 
and gas tube disengaged and sealed.  

 

Warning 

This  unit  may  not  be  used  by  persons  (including 
children)  with  reduced  physical,  sensorial  or  mental 
capacities  or  with  limited  experience  and  familiarity 
unless  they  are  under  supervision  or  instructed  on 
how  to  use  the  unit  by  the  person  responsible  for  its 
safety. 

 

INSTALLATION INSTRUCTIONS 

Warning 

All  of  the operations described in  this  section  must  be 
performed by professional and skilled personnel only. 
 

 
POWER CONNECTIONS 
Warning 

The  power  line  must  be  earthed  and  fitted  with  a 
residual current circuit breaker. 
The  power  cable  must  be  connected  to  a  panel  fitted 
with a cut-out. 

 
Before  plugging  the  heater  into  the  electrical  power  supply,  check 

that the power supply specifications are the same  as those stated on 
the identification plate. 

A  models  may  be  connected  to  a  room  thermostat  or  other 

accessories  (such  as the timer)  by  connecting  to the thermostat  plug 
(10). 

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Ballu-Biemmedue GP 85А C?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"