40

41

This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2019

ENG

Auto shut-off valve knocks

Pressure surges in water mains

Install a check valve on the main pipe in your kitch-

en or at the point of entry of your home’s water 

supply. Refer to a plumber.

The system is always on (water 

is drained continuously)

Water supply pressure too low

This RO system requires at least 3 bar (44 psi) to 

function properly. If necessary, install a pressure 

booster pump or consult a plumber

Pre-filter cartridges are clogged

Replace pre-filter cartridges

Membrane is clogged

Measure flow of product water by closing the tank 

valve and opening the faucet. Measured flow rate 

should correspond to nominal membrane flow 

rate.

Missing or misplaced flow restrictor Flow restrictor must be installed in the tube 

running from membrane housing to drain. Flow 

restrictor must face membrane housing. If it faces 

drain saddle fitting, clean it and swap ends of the 

tube so that it is placed at the outlet of membrane 

housing. If flow restrictor was not installed, install 

one.

Failure of auto shut-off valve

The RO system operating ceaselessly while the 

tank is full may be due to automatic shutoff valve 

failure. Contact the store where you bought 

this product if no other possible cause can be 

established

Failure of check valve in the transi-

tion fitting installed at membrane 

housing permeate outlet

Pressure in the empty tank should be 6-9 psi 

(0.4...0.6 bar). Charge the tank to the above pres-

sure if necessary

Pressure tank is deflated

Open drinking water faucet and let some water 

out. It is normal for the system to stand idle when 

the pressure tank is full of water.

The system will not turn on (no 

water runs to sink drain)

Pressure tank is full

Open drinking water faucet and let some water 

out. It is normal for the system to stand idle when 

the pressure tank is full of water.

Flow restrictor is clogged

Clean or replace flow restrictor

Drain saddle fitting is not centered 

on drain pipe hole

Correctly position the drain saddle

REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE

8. 

TROUBLESHOOTING

Drinking water has a milky or 

cloudy appearance that goes 

away after a few minutes

Air in the system

Some air in the system is normal for a few days 

after the system was installed.

In some cases, air bubbles may appear due to 

supply water being significantly lower temperature 

than your home’s ambient temperature

Water has a taste and/or odor

Carbon post-filter has expired

Replace the post-filter

Preservative solution in the 

 

membrane has not been flushed 

out

Drain all the water from the tank and let the 

system re-fill it

Contamination in reverse osmosis 

system

Sanitize the system per instructions in section 7

Contamination in pressure tank

Replace the tank or sanitize per instructions in 

paragraph 7.1

Pressure tank holds too little 

water

Tank bladder is overpressurized

Pressure in empty tank should be 0.4-0.6 bar (6-9 

psi). Make sure pressure in your tank is in line with 

the above figures

No water is dispensed from 

faucet albeit tank is full

Tank bladder is underpressurized

Pressure in empty tank should be 0,4-0,6 bar (6-9 

psi). Make sure pressure in your tank is in line with 

the above figures

Tank valve is closed

Open tank valve

Содержание

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Ecosoft Absolute 5-50?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"