WarnInG
• Only start cleaning and maintenance once the instructions in the
“Switching off”
section have been completed.
It is particularly important to always disconnect the electricity supply.
• To safeguard the safety of the high pressure cleaner, only use the original spare parts supplied by the Manufacturer
or those endorsed by him.
• The rubber pipes, the coupling and the high-pressure lances are important for safety: only use those endorsed by
the Manufacturer.
7.1 r
outIne
m
aIntenanCe
Follow the instructions in the
“Switching off”
section and abide by the recommendations in the table below.
INTERVAL FOR MAINTENANCE
ACTION
Each time used
• Check the supply cable, high-pressure pipe, couplings, cleaner gun, lance
pipe.
Should any of these parts appear to be damaged, do not use the high
pressure cleaner and contact a Skilled Technician.
Weekly
• Clean the water inlet ilter (26).
Usually, it is suficient to pass the ilter under running water or in a jet of
compressed air to clean it. In more dificult cases, use a lime scale remover or
replace the ilter. Contact an authorised service centre for the purchase of a
new ilter.
Monthly
• Clean the nozzle.
For cleaning, it is generally enough to pass the supplied pin (19) inside the
nozzle hole. In case you do not obtain any appreciable result, apply to an
authorised service centre.
CautIon
• During use, the high pressure cleaner should not be too noisy and large amounts of water or oil should not drip
from underneath it.
In this event, a
Skilled technician
should test the appliance.
7.2 S
PeCIal
m
aIntenanCe
WarnInG
• Only
Skilled Technicians
are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR MAINTENANCE
ACTION
Every 50 hours
Check the pump hydraulic circuit.
Check the pump ixing.
Every 100 hours
Replace the pump oil.
Check the pump suction/delivery valves.
Check the pump screws are tightened.
Check the pump adjustment valve.
Check the safety devices.
CautIon
• the data in the table are indications.
8 D
ISmantlInG
anD
D
ISPoSal
Only trained personnel are allowed to dismantle the high pressure cleaner in accordance with the current regulations
in the country where it is installed.