7.  Cleaning, maintenance, storage 

and ordering of spare parts

Switch o

  the motor and pull the spark plug boot 

from the spark plug before doing any cleaning 

and maintenance work on the equipment.

Notice! Switch o

  the machine immediately and 

contact your service station:

• 

In the event of unusual vibrations or noise

• 

If the engine appears to be overloaded or 

misfires

7.1 Cleaning

• 

Keep all safety devices, air vents and the 

motor housing free of dirt and dust as far as 

possible. Wipe the equipment with a clean 

cloth or blow it with compressed air at low 

pressure.

• 

We recommend that you clean the device  

immediately each time you have finished 

using it.

• 

Clean the equipment regularly with a moist 

cloth and some soft soap. Do not use 

cleaning agents  or solvents; these could 

attack the plastic parts of the equipment. En-

sure that no water can seep into the device.

7.2 Air 

fi

 lter 

In this connection, please also read the service 

information.

• 

Clean the air filter at regular intervals, and 

replace it if necessary.

• 

Open both clips (Fig. 5/A) and remove the air 

filter cover (Fig. 5/B).

• 

Remove the filter elements (Fig. 6/C)

• 

Do not use abrasive cleaning agents or petrol 

to clean the elements.

• 

Clean the elements by tapping them on a flat 

surface. In cases of stubborn dirt first clean 

with soapy water, then rinse with clear water 

and air-dry.

• 

Assemble in reverse order

7.3. Spark plug 

Check the spark plug for dirt and grime after 20 

hours of operation and if necessary clean with a 

copper wire brush. Thereafter service the spark 

plug after every 50 hours of operation.

• 

Pull off the spark plug boot with a twist.

• 

Remove the spark plug (Fig. 7/D) with the  

supplied spark plug wrench.

• 

Assemble in reverse order

7.4 Changing the oil and checking the oil le-

vel (before using the machine)

The motor oil is best changed when the motor is 

at working temperature.

• 

Place the generator on a slightly inclined sur-

face so that the oil drain plug is at the lower 

end.

• 

Open the oil filler plug.

• 

Open the oil drain plug and let the hot engine 

oil drain out into a drip tray.

• 

After the old oil has drained out, close the oil 

drain plug and place the generator on a level 

surface again

• 

Fill in engine oil up to the top mark on the oil 

dip stick.

• 

Important: Do not screw the dipstick in to 

check the oil level, simply insert it up to the 

thread.

• 

Dispose of the waste oil properly.

7.5 Automatic oil cut-out

The automatic oil cut-out responds if there is too 

little oil in the engine. In this case it will not be 

possible to start the engine or it will cut out auto-

matically after a short period of time. It cannot be 

started again until the engine oil has been topped 

up (see point 7.4).

7.6 Maintenance

• 

There are no parts inside the equipment 

which require additional maintenance.

7.7 Storage

• 

Leave the machine to cool (approx. 5 minu-

tes).

• 

Clean the exterior housing of the machine.

• 

Store the machine in a cold, dry place where 

it is out of the reach of ignition sources and 

inflammable substances. 

7.8 Ordering replacement parts:

Please quote the following data when ordering 

replacement parts:

• 

 Type of machine

• 

 Article number of the machine

• 

 Identification number of the machine

• 

 Replacement part number of the part required

For our latest prices and information please go to 

www.Einhell-Service.com

Anl_TC_PG_25_1_E5_SPK9.indb   20

Anl_TC_PG_25_1_E5_SPK9.indb   20

10.02.2022   10:19:26

10.02.2022   10:19:26

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Einhell TC-PG 25/1/E5 (4152600)?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"