BUILT-IN ELECTRIC OVENS
INSTALLATION, USE AND MAINTENANCE INSTRUCTIONS
45
Oven electrical connection
Ensure the electric current has been
disconnected before connecting the oven to the
electric mains.
ATTENTION
If the flexible cable is not intact, to avoid any
risk, it must be completely replaced with a
cable having the same characteristics and
only by qualified staff.
The oven requires single-phase alternate current
220-230-240 V~ 50-60 Hz, using flexible cable.
Ensure the household power supply can support
the electric load of the device. (see serial plate).
The electric safety of this appliance is only assured
if the same is correctly connected to a system
having efficient earth connection, according to
the legal standards in force.
In case of direct connection to the mains (without
the use of the plug) include a device that ensures
disconnection from the network, with a distance
enabling full disconnection in the conditions of
overvoltage category III, in accordance with the
relevant installation regulations.
In models where present, the flexible cable is
supplied without plug. The plug to be used must
be suitable for the electric load of the product and
must comply with the current regulations.
The installer must ensure that the socket is
suitable for the power absorbed by the oven as
indicated on the serial plate.
The connection socket must be easily accessible.
Disconnection of the appliance from the electrical
supply must also be possible after the completion
of installation.
Assembly/replacement of the power supply cable
If the power supply cable is damaged, it must
be replaced by the manufacturer, its after-sales
assistance or by other qualified staff in order to
prevent all possible risks.
The electric cable must be kept secured to the
terminal block by means of a cable fix so that
it cannot come out. Connect the line cable to
terminal L, the neutral cable to terminal
N
and the
yellow/green cable to the earth terminal The
yellow/green cable must be longer than the other
two by at least 20 mm.
Ensure the electric cable does not pass near or
come into contact with the surfaces reaching a
temperature above 75°C.