ENGLISH 

20 

ELECTRIC CONNECTION 
CAUTION! ALWAYS FOLLOW THE SAFETY REGULATIONS. 

 

1.

 

Use is allowed only if the electric system is in possession of safety precautions in 
accordance with the regulations in force. 

2.

 

Ensure that the mains voltage is the same as the value shown on the motor plate and 
that there is the possibility of 

MAKING A GOOD EARTH CONNECTION.

 

3.

 

Pumping stations must always be provided with an automatic switch with an 
intervention current of less than 30 mA.

 

4.

 

Single-phase motors are provided with built-in thermal overload protection and may 
be connected directly to the mains.  

N.B.

  If the motor is overloaded it stops 

automatically.  

Once it has cooled down it starts again automatically without any 

need for manual intervention.

 

5.

 

Three-phase pumps must be protected with motor protectors suitably calibrated 
according to the values on the data plate of the pump to be installed. The plug on the 
pump must be connected to an EEC socket complete with isolating switch and fuses. 

6.

 

Do not damage or cut the power cable.  If this should occur accidentally, have it 
repaired or replaced by skilled and qualified personnel. 

 
 

CHECKING THE DIRECTION OF ROTATION (for three-phase motors) 

 

(Fig.4) 

The direction of rotation must be checked each time a new 
installation is made. 
Proceed as follows 

(Fig.4)

1.

 

Place the pump on a flat surface.

 

2.

 

Start the pump and stop it immediately.

 

3.

 

Carefully observe the kick-back on starting, looking at the 
pump from the motor side.  The direction of rotation is 
correct, that is clockwise, if the protection cap moves as in 
the drawing (anti-clockwise).

 

If it is not possible to check as described above because the pump is already installed, check as 
follows: 
1.

 

Start the pump and observe the water flow rate. 

2.

 

Stop the pump, switch off the power and invert two phases on the supply line. 

3.

 

Restart the pump and check the water flow rate again. 

4.

 

Stop the pump. 

 

The correct direction of rotation will be the one in which the flow rate 
and electric absorption are LOWER! 

 
STARTING UP 

Models with a float switch start up automatically when the water level rises; models without a float 
are started by means of a switch located upstream from the socket (not supplied). 

 
ADJUSTING THE FLOAT SWITCH 

Lengthening or shortening the cable between the float and the fixed point (slot provided in the 
handle - 

Fig.5

) adjusts the START or STOP level of the pump.  Be sure that the float can move 

freely. 

 
 
 
 
 

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к DAB 103040080?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"