Installation
FreshJet
10
•
Before installation, find out (by consulting the manufacturer of the vehicle)
whether the construction is designed for the static weight and the loads of the air
conditioner when the vehicle is in motion. The manufacturer of the roof air
conditioner assumes no liability whatsoever.
•
The vehicle manufacturer may have already provided points where the opening
for the installation of the roof air conditioner can be made without any risk of
weakening the construction or cutting power cables.
•
Select a flat and sufficiently level area at the centre of the vehicle roof between
two longitudinal sections for installation.
•
The roof inclination of the installation surface may not exceed 10°.
•
The roof air conditioner must be installed above 2 meters.
•
Make sure no combustible objects are stored or installed near the air outlet. A
distance of at least 50 cm should be kept.
•
Make sure that there are no objects within the vehicle which could obstruct the
attachment of the air outlet unit or the cooled air from flowing through the
swivelling air distribution nozzles.
•
For safety reasons, note the location of existing wiring harnesses, wires and other
components within the installation area, in particular those which are not visible,
when installing the roof air conditioner (when drilling or screwing etc.).
•
The device shall be installed, operated and stored in a room with a floor larger
than 4 m
2
.
Note on electrical system
•
Only a qualified electrician should connect the roof air conditioner to the
electrical power.
•
Check that the voltage specification on the type plate is the same as that of the
power supply.
•
If the lighting should also be switched on without a 230 V voltage supply, make
sure that there is a 12 V
g
power supply line from the battery to the roof air
conditioner.
•
Do not lay the 230 V mains cable and the 12/24 V
g
cable together in the same
cable duct.
•
Do not lay cables which are loose or bent next to electrically conductive material
(metal).
•
Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
•
If the appliance is powered by the mains, ensure that the 230 V voltage supply
has a residual current circuit breaker.
DometicFJ1700-FJ2000-FJ2200-FJ3200_INM_4445101815_EMEA16_202x-xx-xx.book Seite 10 Mittwoch, 13. Januar 2021 5:16 17
Содержание
- 185 Обращение с прибором; Опасность для жизни из-за поражения электрическим током
- 187 ВНИМАНИЕ! Опасность повреждения; Монтаж устройства
- 188 Целевая группа данной инструкции; Аксессуары
- 189 Использование по назначению; не предназначен
- 190 Заводские таблички; Указания по монтажу; ОСТОРОЖНО! Опасность для здоровья
- 191 Указания по транспортировке; Указания о месте монтажа
- 192 Указания по электрической системе; Изготовление нового отверстия
- 193 Монтаж в имеющемся отверстии люка в крыше; УКАЗАНИЕ
- 194 Прокладка кабелей и проводов
- 197 Крепление накрышного кондиционера
- 198 Электрическое подключение системы
- 200 Установка модуля выхода воздуха ADB