Духовые шкафы Kuppersberg SB 691 W - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

7
ENGLISH
Electric oven
TECHNICAL PASSPORT
Mains frequency detection
At power on, mains frequency is checked.
If 60Hz mains frequency is detected,
the dot between hours and minutes is
illuminated statically, i.e. it remains on
during time flashing. At 50Hz it flashes
together with hours and minutes.
2.2 Power Fail bridging
This feature bridges a short power fail
time. This means when the power comes
back after a short time of power fail,
there is no power on daytime flashing
as after a Reset, but the control returns
with normal operation and times as
before power fail event.
Functional Principle
At normal operation, a backup capacitor
is loaded. When power fail is detected,
daytime and all program parameters are
stored to non-volatile EEPROM.
During power fail, the capacitor is
discharged slowly.
When power returns, first the voltage of
the capacitor is measured. The voltage
level gives information about the
duration of power fail.
When power fail duration is below the
time mentioned in chapter 1.5 [br], the
control is restored by EEPROM
parameters as if no power fail has
happened, i.e. daytime is not flashing
and all programs proceed like before.
So max. loss of daytime is the specified
bridge time.
If power loss lasts longer, the control
restarts with flashing daytime as
described in chapter 2.1.
2.3 Setting Time of Day
At power on, if PLUS/MINUS is pressed,
daytime setting mode is entered and
time is changed immediately. If MODE
is pressed, actual displayed daytime is
overtaken wthout change and EPT turns
to normal operation.
Daytime setting mode is entered by
(successive) pressing mode button. It is
indicated by quickly flashing Clock
symbol. If an automatic program is set,
daytime cannot be changed. If minute
minder is already set, the Minute Minder
symbol is illuminated statically.
Time setting steps and ranges are
described in chapter 1.5 [c] and 4.2. The
minutes change with hour carry-over.
3 Programs
3.1 Program selection
Select programs to set by successive
pressing MODE button. Following
display symbols below hh:mm represent
the selected setting mode: Duration –
End – Bell – Clock - Lock.
- Program time setting modes are:
Daytime, Minute minder, Auto program
duration and end time. 1)Daytime
display
If no program is active, no symbols are
illuminated. Only in this case Operation
Lock
setting is available. If any program is
active
during daytime display, the Clock symbol
flashes slowly.
1) Daytime display
If no program is active, no symbols are
illuminated. Only in this case Operation