www.timberk.com • gas heater

5

Ventilation

During operation, the gas-fired heater burns oxygen contained in air and 

emits carbon dioxide (CO2).
It is important to remember that operation of the gas-fired ceramic heater is 

permitted only in well ventilated rooms. This allows keeping the necessary 

concentration of oxygen in air and removing combustion products.
Operation of the heater in closed and poorly ventilated rooms may create 

The use of ceramic gas heater admissible if: 
1. Gas heater installed on flat surfaces
2. Heat ceramic radiator heater is situated to the back of the gas bag and 

is not directed at him

3. Gas hose conducted with rear heater

Always use only the gas type indicated by the manufacturer.
During operation of the appliance, watch that the gas cylinder is always 

strictly vertical. Use of the cylinder in any other position may result in 

occurrence of an emergency situation, breakdown of the appliance, and 

infliction of a significant damage to you and/or your property.
It is prohibited to move or anyhow cover the heater during operation, as 

well as after shutdown, if the heater is still hot.
The heater should be placed for operation so that its face plate is directed 

towards the room center. At that, distances to walls or other objects on 

sides and behind the appliance should be at least 1 m.

7. CONTROL OF CERAMIC GAS-FIRED HEATER

IMPORTANT! 

All gas joints and pipes should be absolutely tight to 

exclude even slightest gas leaks. Never use matches, 

lighters, and other sources of open flame for leak checks 

of joints. Use soapy water.
It is prohibited to use the gas-fired heater in flats of high-

rise buildings, bedrooms, bathrooms, and cellars.
Upon first ignition, it is recommended to preliminarily 

switch the heater on outdoors, after which it can be 

used indoors. The room, where the gas-fired heater is 

used, should be equipped with natural ventilation.
Do not use the heater during sleep.
Always use only certified, recommended by the 

manufacturer, and properly rated hoses/pressure 

reducers for connection of the appliance.

IMPORTANT! 

Do not start the gas-fired ceramic heater in rooms 

having volume less than 84 m3.
The minimum area of a vent should be at least 105 cm2.
Necessary air exchange 10m3 / hour der 1 kW of 

thermal power heater.

IMPORTANT! 

Never use a gas ceramic heater without attached 

supporting legs

an asphyxiating atmosphere and cause a lack of oxygen. If the oxygen 

concentration decreases below 18%, the ODS system (oxygen detector) 

activates and switches the heater off. In this case it is necessary to ventilate 

the room before restarting the heating mode.

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Timberk TGH 4200 X2?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"