GAS CONNECTION
The oven is designed to operate with both natural
gas (methane) and liquid gas (LPG), and can be
easily converted from one type to another following
the instructions given in the relative section of this
booklet (Conversion to a different type of gas).
At factory the appliance has been pre-installed
to natural gas.
If the appliance is to operate with gas bottles
(LPG), a pressure regulator conforming to the
requirements.
On the pipe
1
is a nut
2
, with a fixed service-
adapter
3
, which is for gas service personal only.
The gas connection with this adapter is prohibited.
Before connecting the gas the service-adapter
3
has to be removed.
Rigid pipe connection
Connection to the mains gas supply may be made
via a metal pipe which is tightly connect to the pipe
1
or via a rigid stainless steel pipe, or via a flexible
steel-tipped hose
4
firmly attached to the fitting
5
.
When connecting to LPG, use fitting
6
instead of
fitting
5
The fittings
5
and
6
with seal are supplied with the
appliance, and comply with standards.
5
should be turned to the optimal
direction for installation and gas connection.
Important
:
Use two wrenches to turn the fitting
5
to the
required position. When the fitting is in the desired
position, firmly tighten nut
2
Attention!
CHECK
UP
LEAK
PROOFNESS of the connection to the gas
supply pipe or gas cylinder using soap
suds only.
Don’t
use open flame
–
danger to life!
Attention!
Connection to the gas supply
and conversion to a different type of gas
must be carried out by qualified technicians
and in conformance with the requirements.
4
2
5
3
1
6
5
2
1