General warnings 

The hot water storage tank has to be put into operation and first started by 
a  professional  technician  in  compliance  with  the  effective  regulations  and 
laws  for  putting  into  operation,  as  well  as  with  any  requirements  of  the 
local  authorities  and  public  health  organisations.  Before  turning  on  the 
heating, the storage tank has to be filled up with water. 

If the hot water storage tank to be put into operation does not only replace 
an  existing  equipment,  but  it  is  part  of  the  renewal  of  the  existing 
hydraulic  system  or  of  a  new  hydraulic  system,  the  company  putting  the 
hot water storage tank into operation – when it has been put into operation 
– shall issue a declaration of conformity, certifying that effective laws and 
specifications  are  met.  The  company  putting  the  equipment  into  operation 
in  both  cases  shall  carry  out  safety  and  operational  checks  for  the  whole 
system. 

Any zincked steel pipe, plastic pipe and red copper pipe can be used as hot 
or cold water pipes. In case of connecting red copper pipes to the pipeline 
system,  the  use  of  insulating  intermediate  pieces  is  compulsory.  It  is 
prohibited to connect the hot water storage tanks with a hose. 

Improper  connection  may  involve  the  injury  of  persons  and  animals,  or  it 
may cause damage to objects. The manufacturer shall not be liable for the 
above. 

It is prohibited to mount a pipeline fitting between the safety valve and the 
equipment. 

It  is  prohibited  to  close  the  outlet  tube  and  to  drain  leakage  in  a  non-
visible way. 

It  is  life  hazardous  and  prohibited  to  put  the  storage  tank  and  the  heat 
exchanger  under  a  pressure  exceeding the allowed operation pressure (0.7 
MPa).  If  the  water  pressure  in  the  system  exceeds  the  value  of  0.6  MPa 
even  temporarily,  a  pressure  reducing  valve  has  to  be  mounted  in  front  of 
the hot water storage tank. 

It  is  prohibited  to  operate  the  hot  water  storage  tank  without  protective 
earthing. 

 
 
 
 
 
 

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Hajdu ID 100 литров, 18.5 кВт ID 25 A?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"