17

CONNECTION TO THE WATER SUPPLY

Inlet and outlet of water are on the water heater pipes marked with colour. The supply of cold 
water is marked with blue, the outlet of warm water is marked with red. The water heater can 
be connected to the water supply in two manners. Closed pressure system of connection 
enables the outlet of water on several outlet spots, non-pressure system enables only one 
outlet point. With regard to the system of connection chosen, also the suitable mixing taps 
must be purchased. By open non-pressure system it must before the water heater a non-
return valve be built-in preventing the running of water of the tank if in the network the water 
runs short. By this system of connection, the cross-flow mixing tap must be used. In the water 
heater, due to the heating the volume of water is increasing, which causes the dropping of 
water of the mixing tap pipe. By strong squeezing of knob of the mixing tap the dropping of 
water can not be prevented, but the mixing tap can only be damaged. 
By closed pressure system of connection on the outlet spots the pressure mixing tap must 
be  used.  For  safety  reasons  the  supply  pipe  must  be  fitted  with  a  return  safety  valve  or 
alternatively, a valve of the safety class that prevents the pressure in the tank from exceeding 
the nominal pressure by more than 0.1 MPa.
The heating of water in the heater causes the pressure in the tank to increase to the level set 
by the safety valve. As the water cannot return to the water supply system, this can result in 
the dripping from the outlet of the safety valve. The drip can be piped to the drain by installing 
a catching unit just below the safety valve. The drain installed below the safety valve outlet 
must be piped down vertically and located in the environment that is free from the onset of 
freezing conditions. In case the existing plumbing does not enable you to pipe the dripping 
water  from  the  return  safety  valve  into  the  drain,  you  can  avoid  the  dripping  by  installing  a 
3-litre expansion tank on the inlet water pipe of the boiler.
You  should  ensure  that  the  return  safety  valve  is  functioning  properly  by  checking  it  on  a 
regular basis i.e. every 14 days. To check the valve, you should open the outlet of the return 
safety valve by turning the handle or unscrewing the nut of the valve (depending on the type 
of the valve). The valve is operating properly if the water comes out of the nozzle when the 
outlet is open.

GB

GBFU 50 N (UNI) GBFU 80 N (UNI) GBFU 100 N (UNI) GBFU120 N (UNI) GBFU 150 N (UNI)

A

583

803

948

1103

1318

B

365

565

715

865

1065

C

185

205

200

205

220

D

145

345

495

645

845

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Gorenje GBFU200B6?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"