Scope of supply
467 769_a
11
corrosive, flammable, explosive or fuming
fluids
fluids that are hotter than 35 °C
water containing sand and abrasive fluids.
➯
only on Drain pump
SCOPE OF SUPPLY
Thermal protection
The equipment is fitted with a thermal protection
switch which switches the motor off in the event
of overheating. After a cooling-down phase of ap-
prox. 15 - 20 minutes the pump switches on auto-
matically.
Operate the unit only if the immersion pump is fully
immersed.
SAFETY INSTRUCTIONS
CAUTION!
Danger of injury!
Only use the machine and the extension
cable if it is in perfect technical condition!
Damaged units must not be used.
Safety and protective devices must not
be deactivated!
Children, or people who are not familiar with
the operating instructions, are not allowed to
use the machine.
Never lift, transport or suspend the unit using
the connection cable.
Unilateral modifications or conversions of the
unit are prohibited.
Electrical safety
CAUTION!
Danger when touching voltage con-
ducting parts!
Disconnect the plug from the mains if the
extension cable is damaged or severed!
We recommend connecting a RCD (re-
sidual current operated device) having a
nominal residual current of < 30 mA.
The house mains voltage must agree with the
details quoted in the technical data, do not
use any other supply voltage.
The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702 (swimming
pools). Protection must be provided by a 10 A
line protection switch and a RCCD (residual
current operated device) having a nominal re-
sidual current of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
2
. Cable drums should always be unrolled
completely.
Damaged or brittle extension cables must not
be used.
➯
Check the condition of your extension
cable each time you start to use the
equipment.
ASSEMBLY
Mounting the pressure line
see Fig. A
1. Screw the connection elbow
(7)
into the pump
outlet.
2. Screw the combination nipple
(5)
into the con-
nection elbow.
3. Fix a hose to the combination nipple.
ADVICE
The combination nipple can be trim-
med to suit the selected hose con-
nection. Use the largest possible
hose diameter.
STARTUP
Safety
CAUTION!
Exclude, by suitable means, that, in the
event of a fault in the immersion pump,
consequential damage is caused by floo-
ding.
Make sure that the immersion pump is stan-
ding securely or operate the immersion pump
suspended from a rope.
Make sure there is adequate clearance under
the pump.
Never allow the immersion pump to run
against a closed off pressure line.
When using in shafts, make sure the size is
adequate.
Always cover the shaft with a secure foot-
plate.
Содержание