IPC Portotecnica SIBI MAX 5160 T 43212 IDAF - Инструкция по эксплуатации - Страница 16

Мойки высокого давления IPC Portotecnica SIBI MAX 5160 T 43212 IDAF - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.

Если остались вопросы, задайте их в комментариях после инструкции.

"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.
Страница:
/ 84
Загружаем инструкцию
background image

English

- 16 -

CLASSIFICATION

The  user  must  observe  the  conditions  of  use  of  the  applian-

ce prescribed  by  the  Rules,  and  particularly  he  must  respect 

the following classification:

As  for  the  protection  against  electric  shock,  the  H.P.cleaner 

belongs to 

CLASS I.

The  H.P.  cleaner  is  factory  set    and  all  its  safety  devices  are 

sealed. 

It is forbidden to alter their adjustment values.

The  H.P.  cleaner  must  be  always  used    on  a  firm    and  flat 

ground, furthermore it must not be moved while it is working or 

connected to the electric supply.

The water cleaner is considered as a fixed device.

Failure to observe this prescription may cause danger for the 

user.

The H.P. cleaner must not be used in the presence of corrosive 

or potentially explosive atmospheres. (vapours or gas)

The electric connection must be performed by qualified tech-

nicians who are  able to work in observance of the governing 

rules (as far as Italy is concerned please refer to the law 46/90) 

and of the manufacturer’s instructions.

A  wrong  electric  connection  may  cause  damage  to  persons, 

animals or things, and the manufacturer  cannot be considered 

responsible for these.

 

The contents of this booklet must be brought to the attention 

of  persons  using  or  carrying  out  routine  maintenance  on  this 

water cleaner.

The most important instructions 

are marked with the symbol:

  

INTRODUCTION

     

      This manual must be read before installing, setting up and 

using the cleaner.  The manual is an integral part of the product.  

It is composed of two parts, one of which is yellow.

Read the warnings and instructions in this manual carefully as 

they provide important indications as to 

SAFETY IN USE and 

MAINTENANCE

, paying special attention to the general rules 

for safety listed in the yellow booklet.

KEEP  THIS  MANUAL  CAREFULLY  FOR  FUTURE  CON-

SULTATION.

The  H.P.  cleaners  with  power  lower  than  3  kW  are  equipped 

with a plug for  connection to the electric supply.

In this case please check if the electric power system and the 

electric  sockets  are  compatible  with  the  max.  power  of  the 

appliance indicated on the plate. (kW)

In case of doubt, please apply to qualified personnel.

If the socket and the plug of the machine are not compatible, 

have  the  plug replaced  with  a  suitable  type  by  qualified  per-

sonnel.

 

Before  connecting  the  machine  make  sure  that  the  data 

indicated on the plate correspond to those of the electric sup-

ply.

Do not use extensions to feed the H.P. cleaner.

The electric safety of this machine may be assured only when 

it  is  properly  connected  to  an  efficient  grounding  system  in 

accordance with the governing laws for electric safety. (As far 

as Italy is concerned, please refer to the law 46/90)

It is necessary to check this essential safety requisite. In case 

of doubt,  ask  for  accurate  control  of  the  power  system  by 

qualified personnel.

The manufacturer may not be considered responsible for dama-

ges occurred because of the lack of the grounding system.

The H.P. cleaner must be connected to the electric supply by 

means of an omnipolar switch with opening contacts of at least  

3 mm. This switch must have electric features which are consi-

stent with the appliance. (This requisite does not apply to H.P. 

cleaners with plug and electric power lower than 3 kW)

The appliance is disconnected from the electric supply only by 

pulling out the plug or switching off the omnipolar switch.

      Water cleaners with the “Total Stop” device should be con-

sidered as off when the omnipolar switch is in the “O” position 

or the plug is unplugged from the socket.

INTENDED USE

This appliance is intended exclusively for cleaning machines, 

vehicles, buildings and general surfaces suitable for treatment 

with a high pressure jet of detergent solution  between 25 and 

350 bar (360 - 5150 PSI).

This appliance has been designed for use with the detergents 

supplied  or  recommended  by  the  manufacturer.    The  use  of 

other detergents or chemicals may influence the safety of the 

appliance.

This appliance must be used only for the purpose for which it 

was specifically designed.

All  other  uses  are  to  be  considered  incorrect  and  therefore 

unreasonable.

!

!

!

!

!

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к IPC Portotecnica SIBI MAX 5160 T 43212 IDAF?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"