plug and the drainage cover.
4:Remove the exhaust pipe and keep it properly.
5:Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place,
keep it out of the reach of children, and take dust control measures.
6:Remove batteries of the remote control and keep them properly.
Note:
ensure that the body is placed in a dry place and keep all machine components
properly.
10. SAFETY PRECAUTIONS ON SERVICING
- Read the technical manual
ATTENTION!
Any person involved in service work on the device or intervention in the refrigerant
circuit must go through special training, confirmed by a certificate.
Please follow these warnings when to undertake the following when servicing a
dehumidifier with R290.
1. Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks
are necessary to ensure that the risk of ignition is minimized. For repair to the
refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
2. Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a
flammable gas or vapor being present while the work is being performed.
3. General work area
All maintenance staff and others working in the local area shall be instructed on the
nature of work being carried out. Work in confined spaces shall be avoided. The area
around the workspace shall be sectioned off. Ensure that the conditions within the area
have been made safe by control of flammable material.
4. Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during
work, to ensure the technician is aware of potentially flammable atmospheres. Ensure
that the leak detection equipment being used is suitable for use with flammable
refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.
5. Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated
parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry
powder orCO
2
fire extinguisher adjacent to the charging area.
Содержание
- 2 ВАЖНАЯ ИНФОРМАЦИЯ; описываются; ПРИМЕЧАНИЕ
- 7 УСТАНОВКА ПРИБОРА
- 8 Рис.3 Рис.4; Установка кондиционера в помещении
- 9 Панель управления
- 10 Пульт управления
- 11 Защитные функции прибора; Функция заполненности конденсатом:; ВНИМАНИЕ! Перед очисткой прибора отключите его от электросети.; двигайте прибор осторожно, во избежание пролива воды на дно
- 12 Автоматический слив конденсата (; опционально, работает только в режиме; Установите дренажную трубку* в сливное отверстие.
- 15 применяться следующие проверки:; . Проверки электрических устройств; Первоначальные проверки безопасности должны включать:
- 20 Переустановите температуру.
- 21 УТИЛИЗАЦИЯ, СРОК СЛУЖБЫ, ГАРАНТИЙНЫЙ СРОК; потребителя иили третьих лиц, а также в случае ситуаций, вызванных; ТРАНСПОРТИРОВКА И ХРАНЕНИЕ; перемещения упаковки внутри транспортного средства.