34

The cappuccino system is not drawing up
any milk.
The cappuccino system produces little to
no foam.

Check that the system is properly assembled.
Check that the setting knob is on the CAPPUCCINO position.
Check that the steam outlet is not blocked.
Check that the flexible tube is not obstructed or pierced and that it
is properly fitted into the cassette so as to avoid any air intake.
Check that the milk suction tube is properly immersed in the milk.
Rinse and clean the system (see corresponding chapter).
For  milk-based  preparations:  we  recommend  using  recently
opened fresh, pasteurised or UHT milk. It is also recommended to
use a cold container.

The coffee flows too slowly or does not flow
at all.

Turn  the  grind  fineness  button  to  the  right  to  obtain  a  coarser
grind (may depend on the type of coffee bean used).
Perform one or several rinse cycles.
Run a damp sponge under the coffee outlet.

The espresso or coffee is not hot enough.

Change the coffee temperature setting .
Heat the cups by rinsing them under hot water.

The coffee is too light or not full-flavoured
enough.

Check that the coffee bean reservoir contains coffee and that it
is flowing properly.
Avoid using oily, caramelised or flavoured coffee.
Reduce the volume of coffee using the + and - buttons.
Turn the grind fineness knob to the left to obtain a finer grind.
Make your preparation in two cycles by using the 2-cup function.

The coffee is too acidic

The infusion temperature is too low
The water is too acidic

The coffee is too bitter

The infusion temperature is too high
The level of grinding is too fine
The water is too hard

The coffee has little aroma

The infusion temperature is too low
The ground coffee is too old
The grind is too coarse
The water is too soft/alkaline

The coffee has no body

The infusion temperature is too low
The ground coffee is too old
The grind is too coarse
The water is too soft/alkaline

The coffee is not very creamy.

Turn  the  grind  fineness  knob  to  the  left  for  a  finer  grind  (may
depend on the type of coffee used).
Change the Aqua Filter System cartridge (follow the installation
procedure on page 3).
Perform one or several rinse cycles.

The cappuccino foam is too liquid

Use fresh (3/5C°), UHT or whole milk.
Check that the milk pot and the tube are not obstructed

DRINKS

KR_ARABICA-LATTE_EA819_8020002251_EN.qxp_Mise en page 1  17/08/2018  14:02  Page34

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Krups EA819N10?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"