10

and waiting for a moment, the appliance 

begins  to  be  heated  until  the  green 

lamp is illuminated, it shows the heating 

is finish. 

5.  Remove  the  frothing  device  from  the 

steam wand.

6.  Dip  the  steam  wand  into  the  liquid  to 

be  heated.  Turn  the  steam  control  knob 

in  anti-clockwise  slowly  to  start  making 

steam.

7.  When  the  required  temperature  is 

reached, you can turn  the steam  control 

knob to the minimum position.

8.  Press  and  release  the  ON/OFF  button 

to  the  higher  position  which  is  the 

O F F

”  position  to  cut  the  power  source 

off.

CLEAN AND MAINTENANCE:

Cut  off  power  source  and  let  the  coffee 

maker  cool  down  completely  before 

cleaning.

Clean  housing  of  coffee  maker  with 

moisture-proof  sponge  often  and  clean 

water  tank,  drip  tray  and  removable 

shelf regularly then dry them. 

Note:

  Do  not  clean  with  alcohol  or 

solvent  cleanser.  Never  immerse  the 

housing in water for cleaning.

Detach  the  metal  funnel  through  turn  it 

clockwise,  get  rid  of  coffee  residue 

inside,  then  you  can  clean  it  with 

cleanser, but at last you must rinse  with 

clear water.

Clean  all  the  attachments  in  the  water 

and dry thoroughly.

CLEANING MINERAL DEPOSITS 

1.  To  make  sure  your  coffee  maker 

operating  efficiently,  internal  piping  is 

cleanly  and  the  peak  flavor  of  coffee, 

you  should  clean  away  the  mineral 

deposits left every 2-3 months.

2.  Fill  the  tank  with  water  and  descaler 

to  the  MAX  level  (the  ratio  of  water  and 

descaler  is  4:1,  the  detail  refers  to  the 

instruction  of  descaler.  Please  use 

“household  descaler”,  you  can  use  the 

citric  acid  (obtainable  from  chemist’s  or 

drug stores) instead of the descaler (the 

one  hundred  parts  of  water  and  three 

parts of citric acid).

3.  According  to  the  program  of  pre-

heating,  put  the  metal  funnel  (no  coffee 

powder  in  it)  and  carafe  (jug)  in  place. 

Brewing water per “PRE-HEATING”.

4. Press down the ON/OFF button  to the 

” 

lower  position  which  is  the  “ 

position,  the  power  indicator  (red)  will 

be  illuminated,  you  should  press  the 

pump  control  button  to  the  lower 

11

position  which  is  the 

position,  make 

sure  the  coffee/steam  button  is  on  the 

higher  position  which  is  the 

position,  when  there  is  water  flowing 

out  and  close  the  pump  by  pressing  the 

pump  control  button  again  to  the 

S T O P

”  position,  and  waiting  for  a 

moment,  the  coffee  maker  begins  to  be 

heated. 

5.  When  the  ready  indicator  (green)  is 

illuminated,  it  shows  the  heating  is 

finish.  Pressing  down  the  pump  control 

button to the lower position which is the 

”  position  and  make  two  cups 

coffee  (about  2Oz).  Then  close  the 

pump and wait for 5s.

6.  Press  down  the  coffee/steam  button 

to  the  lower  position  which  is  the 

position,  waiting  for  until  the  green 

indicator  is  illuminated.  Make  steam  for 

2min,  then  turn  the  steam  control  knob 

to the  minimum position to stop making 

steam. Press and release the  ON/OFF to 

the  higher  position  which  is  the  “

O F F

” 

position  to  stop  the  unit  immediately, 

make  the  descalers  deposit  in  the  unit 

at least 15 minutes.

7.  Restart  the  unit  and  repeat  the  steps 

of 4-6 at least 3 times.

8.  Then  pressing  and  release  the 

coffee/steam  button  to  the  higher 

position  which  is  the 

position,  when 

the  green  lamp  is  illuminated,  press 

down  the  pump  control  button  to  the 

lower  position  which  is  the  “

” 

position to brew until no descaler is left.

9.  Then  brewing  coffee  (no  coffee 

powder)  with  tap  water  in  the  MAX 

level, repeat the steps of 4-6 for 3 times 

(it  is  not  necessary  to  wait  for  15 

minutes in step of 6), then brewing until 

no water is left in the tank.

10. Repeat the step of 9 at least 3 times 

to make sure the piping is cleanly.

TROUBLE SHOOTING 

Symptom

Cause

Corrections 

There 

is 

much  water 

in  the  drip 

tray.

Please clean 

the 

drip 

tray.

Water 

leaks 

from  the 

bottom  of 

coffee 

maker.

The 

coffee 

maker 

is 

malfunction.

Please 

contact with 

the 

authorized 

service 

facility  for 

repairing.

Water 

leaks  out 

of  outer 

side 

of 

filter.

There 

is 

some  coffee 

powder 

on 

filter edge.

Get  rid  of 

them.

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Saturn ST-CM7089?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"