in auto ventilation mode is detected
If possible, perform calibration in an odour-
free environment with no “cooking events” in
progress.
For sensor calibration, proceed as follows:
- press T4 for 5 seconds, with the motor
switched off.
Calibration will last 15 minutes with:
- motor switched on according to speed
- T4 flashing;
If calibration has been performed correctly:
- the motor switches off
- T4 switches off (low-intensity light)
NB = press T4 for 5 seconds to stop
calibration; calibration will result cancelled
and must be repeated.
T4 - Motor ON/OFF
SL2 - Increase/Decrease motor speed
- press T4 to switch on the motor
- skim your finger to the right over the
control to increase the motor speed
(speed 1
--- > speed 9)
;
- skim your finger to the left over the control
to decrease the motor speed
(speed 9 --- >
speed 1);
- press T4 to switch off the motor
T5 - Timing
(intensive : speed 10)
- press T5 to activate the timing function:
the hood will remain at speed 10 for 5
minutes, then it will go back to the previous
setting;
- press T5 to deactivate the timing function.
T6 - Timing X2
(intensive : speed 11)
- press T6 to activate the timing function
- the hood will remain at speed 11 for 5
minutes, then it will go back to the previous
setting;
- press T6 to deactivate the timing function.
T7 - Refresh function
- press T7 to activate the refresh function
- 50 minutes after being switched off, the
hood switches on again automatically at
speed 1 for 10 minutes; then it will switch off
again.
- press T7 to deactivate the refresh function
NB =
the function is active when T7 is lit
T8 - Timer/Automatic switch off
- press T8 to activate the function (manually
when the hood is on - not with timing or auto
ventilation),
- on
pressing once,
the time will
be set to switch off after 10
minutes;
NB = the function is active when
T8-1 is lit
- on
pressing twice,
the timer
will be set to switch off after 20
minutes;
NB = the function is active when
T8-2 is lit
- on
pressing three times,
the
timer will be set to switch off after
30 minutes;
NB = the function is active when
T8-3 is lit
after selecting the desired time, release T8;
the countdown will start after 5 seconds.
- after the set time has elapsed, the hood
will switch off automatically
T9 - Charcoal filter use status
- to activate the function,
press T8+T9 simultaneously for three
seconds with the hood switched off;
NB = T9 lights up, the function is activated
- to deactivate the function,
press T8+T9 simultaneously for three
seconds with the hood switched off;
NB = T9 flashes, the function is deactivated.
The charcoal filter saturation warning
is
displayed after 160 hours of use and is
signalled by T9 flashing; when this warning
appears, the carbon filter must be replaced.
After performing maintenance: