Operation
Use the high suction speed in cases of concentrated kitchen 
vapours.  It is recommended that the cooker hood suction is 
switched on for 5 minutes prior to cooking and to leave in 
operation during cooking and for another 15 minutes 
approximately after terminating cooking.  
 
 
 
1 ON/OFF
motor
Pressing the button, the hood turns on at speed 1.
Pressing the button during functioning, the hood turns 
OFF. 
2 Speed
Increase
Pressing the button the hood passes from the OFF state 
to speed 1. 
Pressing the button (hood in ON state) the motor speed 
is increased from speed 1 to intensive. 
To each speed corresponds the ignition of the respective 
led. 
Speed 1 led
L1
Speed 2 led
L2
Speed 3 led
L3
Intensive Speed led
L4
(flashing)
The intensive speed is timed. The  standard timing is 5’, 
at the end of which the hood positions itself to speed 2. 
To deactivate the function before the time expires press 
key 
2
, the hood positions itself to speed 1, pressing key
1
the hood will turn off.
3 ON/OFF
lights
4 Speed
timing
5 Function state indicator
Speed Timing
The timing of the speed is enabled by pressing key
4
, once
the timing expires the hood turns off. 
The timing is subdivided as follows: 
Speed 1 - 20 minutes (led 
L1
flashing)
Speed 2 - 15 minutes (led
L2
flashing)
Speed 3 - 10 minutes (led
L3
flashing)
Intensive Speed - 5 minutes (led
L4
flashing)
 
During the timed functioning pressing key 
1
the hood turns off,
if you press key
2
or key
4
the hood returns to the set speed.
Grease trap Signal
After 40 hours of operation the led
L5
turns on.
When such signal appears the installed grease trap needs to 
be washed. 
To reset the signal hold down key 
1
for 3”.
Carbon filter Signal
After 160 hours of operation the led
L5
flashes.
When such signal appears the installed carbon filter must be 
substituted. 
To reset the signal hold down key 
1
for 3”.
 
In the case of both filters signalling at the same time, the led 
L5
will indicate the alarms alternately remaining on for 3" and
subsequently flashing 3 times. 
The reset takes place by carrying out the procedure described 
above 2 times. 
The first time resets the grease trap signal, the second resets 
the carbon filter signal. 
 
In the standard mode the carbon filter signal is not active. 
In case one uses the hood in filter version is it necessary to 
enable the carbon filter signal. 
 
Carbon filter signal activation:
Position the hood in OFF and simultaneously hold down keys
1
and
4
for 3”.
The led
L1
and
L2
will flash for 5”.
Carbon filter signal deactivation: 
Position the hood in OFF and simultaneously hold down keys 
1
and
4
for 3”.
The led
L1
will flash for 2”.
Temperature Alarm
The hood is equipped with a temperature sensor that activates 
the motor to speed 3 in the case that the temperature in the 
control zone becomes too elevated. 
The alarm condition is indicated with the sequential flash of 
the leds 
L1
,
L2
,
L3
.
This condition remains until the temperature falls below the 
alarm threshold. 
You can get out of this mode by pressing key 
1
or
2
.
Every 30” the sensor checks the environmental temperature of 
the display zone. 

 
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 