3. WHEN INSTALLING AND OPERATING THE EWH, IT SHALL BE FORBIDDEN TO:

connect the power supply if the EWH is not filled with water;

џ

remove the protective cover when the power is on;

џ

use the EWH without grounding or use water pipes as grounding;

џ

plug  the  EWH  in  the  water  supply  system  with  a  pressure  of  more  than  0,6  MPa.  If  the

џ

pressure  in  the  water  supply  system  exceeds  0,6  MPa  or  is  not  stable  and  periodically
exceeds 0,6 MPa, it is necessary to install a suitable reducing valve (not included in the EWH
supply  package)  at  the  inlet  of  cold  water  in  the  EWH,  in  front  of  the  relief  valve  (in  the
direction of water flow) in order to reduce the pressure of cold water until it becomes normal.
It shall be forbidden to install a pressure control valve between the EWH and the relief valve;
connect the EWH to the water supply line without a relief valve;

џ

drain water from the EWH when the power is on;

џ

use spare parts not recommended by the manufacturer;

џ

use water from the EWH for cooking;

џ

use  water  containing  mechanical  impurities  (sand,  small  stones)  that  can  lead  to  the

џ

malfunction of the EWH and relief valve;
switch on and use the EWH with closed input and output valves (branch pipes).

џ

change the design and mounting dimensions of EWH brackets;

џ

4.

 Freezing of water in the device is unacceptable, as this leads to its failure, which is not a warranty

case.

5.

 The EWH is not intended for use by persons with reduced physical, tactile, or mental capabilities, or

by persons who cannot use the EWH, except when it is monitored or in accordance with instructions
from persons responsible for EWH safety. Children can use the EWH only under the supervision of
persons  who  know  how  to  safely  operate  it.  One  shall  always  bear  in  mind  that  there  is  a  risk  of
scalding with water and electric shock.

6.

 If the buyer does not comply with Clauses 1 – 4 of this section, the manufacturer's warranty shall be

canceled.

7.

 It shall be forbidden to leave the EWH switched on in the power supply network in the absence of

supervision for more than 1 day.

Description and principle of operation

The EWH consists of casing, a heating element, a thermostat, a relief valve, and a protective cover 
with control elements.

The  EWH  casing  consists  of  a  steel  tank  thermally  insulated  with  environmentally  friendly 
polyurethane foam and two threaded pipes: cold water inlet pipe (with a blue ring) and hot water outlet 
pipe (with a red ring). The inner tank has a special glass-porcelain coating, which reliably protects the 
inner surface from chemical corrosion.

The  following  components  are  mounted  on  a  removable  flange 

(3) Fig.1

«dry»  heating  element 

CeramicHeat in a 

(7)

(8)

(9)

protective envelope 

, a thermostat 

, and a magnesium anode 

. The heater 

is used for heating water, and the thermostat makes it possible to adjust the heating temperature to 
+7 °C (± 5°C).

4

19

EN

The  CeramicHeat 

«

dry

»

  heating  element  is  designed  for  the  reliable  operation  in  any  region  with 

water  of  various  levels  of  hardness  and  mineralization.  The  heating  contour,  located  inside  an 
enameled protective envelope, has no direct contact with water, and therefore it is protected from 
scale  and  corrosion.  The  heating  effectiveness  is  enhanced  due  to  the  increased  area  of  the 
envelope.  The  heating  is  performed  with  help  of  a  nickel-chromium  spiral,  located  between  heat-
absorbing ceramic elements that heat the envelope uniformly. The heating ceramic element warms 
up  and  cools  down  smoothly  that  helps  to  reduce  scale,  ensuring  a  long  service  life  of  the 
CeramicHeat.  Due  to  the  minimum  scale  generation,  the  water  quality  is  also  enhanced.  The 
replacement  of  the  CeramicHeat    ceramic  element  with  a  heating  spiral  can  be  executed  without 
water drain.

The magnesium anode is designed to neutralize the effects of electrochemical corrosion on the inner 
tank.

The water temperature in the inner tank is adjusted by means of the thermostat handle 

located on 

(10)

the protective cover of the water heater. The thermostat also contains a thermal switch – the device 
protects the EWH from overheating, which disconnects the heater from the power supply network 
when  the  water  temperature  exceeds  +93°

(±5° ).  EWH  may  heat  up  during  operation.  The 

С

С

activation of the thermal protection of the water heater is not its malfunction. To return the water heater 
to  the  working  state,  press  the  thermoswitch  rod  located  under  the  protective  cover  of  the  EWH

.

(Fig. 3)

The relief valve functions as a non-return valve by preventing the water from entering the water pipe in 
case of pressure drop in the latter and in case of increase in the pressure in the tank with strong water 
heating and as a relief valve by relieving the overpressure in the tank when the water is heated up 
strongly.

Depending on the EWH model, the protective cover 

has one or two control lamps indicating the 

(4)

instrument operation or power selection keys.

In models with a single control lamp, the lamp indicates the EWH operation mode – it is lit up when the 
water is heated and goes out when the set temperature has been reached.

In models with two control lamps, the 

Lamp indicates the EWH operation mode – it is lit up 

«

Heating

»

when the water is heated and goes out when the set temperature has been reached. The 

«

Power

»

Lamp is lit up constantly it indicates the device connection to the power supply network.

 – 

For models with power selection keys, the indicator of the EWH operation mode is used for the lamps 
intended for highlighting power selection keys

they are lit up when the water is heated and go out 

– 

when the set temperature has been reached.

A  Residual  Current  Device  is  mounted  on  the  EWH  electric  cord,  which  ensures  the  EWH 
disconnection  from  the  power  supply  network  when  a  leakage  current  appears  on  the  grounded 
elements of the electrical appliance.

Placement and Installation

It is advisable to install the EWH as close as possible to the place of use of hot water in order to reduce 
heat losses in the pipes.

18

EN

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Thermex ERD 100 V (pro)?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"