The order of working
The flow-type water heater works automatically. For the working of the water heater it is
recommended to have a pressure not less than 25000 Pa and the output flow of water not less
than 1,5 liters per minute. The maximum working pressure is 600000 Pa. The water heater
switches on automatically when the tap on the water inlet is open and the “temperature control”
is on. The water heater switches off automatically when the tap on the water outlet is closed and
the “temperature control” is off.
О
pen the water flow with the help of the tap on the water inlet
and turn on the “temperature control” regulator. You can choose the necessary temperature with
the help of “temperature control”: To switch the heater off it is necessary to set the “temperature
control” in “OFF” and to close the tap. After that the power supply can be switched off.
Technical service regulation
In the durative process of exploitation, when the warranty period is over, it is necessary to make
routine repairs once or twice a year.
- Turn the water heater off the main electrical supply
- Examine the water heater carefully , clean the water heater with the duster, check the water
pipes, remove the corrosion (if it is necessary to blow off) and cover with the layer of protective
lubrication.
ATTENTION!
Be careful! There mustn’t be any obstructions in the water outlet hose and shower- head.
- clean the injectors of the shower-head
- make the shifting of the screwed connections.
If the hydraulic drop (water flow) become worse, you should clean the rings
of the water heater
and a strain (filter) which is set up at the
inlet of the water heater.
Trouble shooting
The functioning of the heater can be tested after installation as follows—turn it on and press the
"supply choice button" for maximum heat, with the shower head also set for Winter (few "holes"
open for maximum heat). Now, set the water flow to minimum. The heater is working well if the
water becomes hot.
There are common installation problems:
Problem
Reason and solving method
When the water is very
hot, but only for a
short time, and then
the water becomes
very
hot
again
briefly but for a short
time also.
It means that the heater has been installed incorrectly and
that the outlet is being obstructed by some tap or other
object. The tap must be located at the inlet of the heater!
Use only the parts supplied with the heater at the outlet!
The heater heated the
water as expected,
but only for a short
time and not again.
The protective fuse blew out, because it was unsuited to the
power of the heater installed.
The heater is not heating.
Check to be sure that only parts supplied with the heater are
attached at the outlet! Make sure that the tap at the inlet
is a regular one, not a brass ball faucet/level tap, so that
the water flow can be finely controlled.