TROUBLESHOOTING
MAINTENANCE
When a malfunction occurs, the user interface of the appliance can display an error code.
1. FLAT RANGE
2. SQUARE RANGE
Nothing
CAUTION
: Before removing the plastic cover, make sure the power is turned off to avoid any risk of injury
or electric shock.
1. USER MAINTENANCE
Operates once a month the discharge of the safety valve to prevent scaling deposit and verify that
the safety device is not blocked.
If this is not done, damage may be caused and the guarantee invalidated.
For an installation with a booster pump; before starting up, after a long period of disuse, turn the rotor fol-
lowing the advice in the manufacturer’s instructions.
2. MAINTENANCE BY A QUALIFIED PERSON
- Scaling: Remove the scale sludge. Do not scrape or hammer the lime scale deposited on the casing,
as this may damage the lining.
-
Magnesium anode: change the magnesium anode every 2 years or when its diameter is lower than 10 mm.
- Heating element: the replacement of a sheathed heating element involves draining of the water
heater and replacement of the fl ange gasket. Reassemble the heating element, reasonably tight nuts
(cross tightening), check that there is no leakage after the fi rst heating-up, tighten again if necessary
-
Drain: Turn off power and cold-water supply. Open hot water taps and drain valve of the safety device.
Spare parts list
: thermostat, fl ange gasket, heating element, heating light indicator, magnesium anode,
connection wires, electric switch. The guarantee requires genuine manufacturer’s parts to be used.
Advice to the user
²
When the water has a TH > 20°f, it is recommended that this be treated. When a softener is used, the water
hardness must remain above 15°f.
²
In case of prolonged absence, especially in winter, drain your appliance following the procedure above.
Fault (LED status)
Meaning
Remark
2 successive «shower» blinking, 3 sec of
pause, 2 successive shower blinking…
Error 3 :
Probe fault
Change probe
2 successive «shower» blinking, 3 sec of
pause, 4 successive shower blinking
Error 9 :
Relay or PCB fault
Change PCB
Характеристики