f) Remain seated quietly for 2 minutes before you 

begin the measurement.

Comment:

If it is not possible to fit the cuff to the left arm, it can also 
be placed on the right one. However all measurements 
should be made using the same arm

5.4. Setting the inflation pressure

Program the inflation pressure to be approximately 40 mmHg higher than your estimated systolic blood
pressure. You can choose between 8 initial values: 140, 160, 180, 200, 220, 240, 260 and 280 mmHg. If
you do not know your systolic blood pressure, select a value between 160 and 200. The instrument is pre-
set to 140 mmHg. If this initial value is sufficient for you, omit the following step and start immediately
with the measurement.

Set the initial pressure as follows:

a) Switch on the instrument by pressing the O/I button. 

This picture appears on the LCD display. (It remains

there as long as you hold the button pressed down).

b) After the button is released, the display flashes as 

shown and the instrument beeps. This indicates that

the instrument is automatically adjusting itself to
the pressure of the surroundings.

c) After this equalization is completed, zero is displayed.

Finally a beep is emitted to indicate that the instru-
ment is ready to take measurements.

d)  On pressing the SET button the instrument displays 

the pre-set initial pressure for approx. 3 seconds.

e) In order to set the initial pressure individually, press 

the SET button briefly for each level until the required 
initial pressure is reached. Each button press raises 
the initial pressure by 20 mmHg. After reaching 
280 mmHg the display starts again at 120 mmHg.

f) After the SET button has been released, the instru-

ment is set to the displayed value and the setting up 
procedure is complete. As long as the batteries are 
not removed, the value is stored in the instrument 
even after it has been switched off.

Comment: 

If the initial pressure selected was too low it will be corrected automatically during the measurement by 
additional inflation. This results in a slightly longer measuring procedure which the patient may find
uncomfortable. The result of the measurement is normally not affected.

7

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Microlife BP 2BHO?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"