Пылесос Bosch Serie|4 BGS2U2030 - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

45
Controlling the
s
uction level
Fig.
8
Turn the control knob to infinitely adjust the suction
level to the level required.
Low power range
>
= For vacuuming delicate materials, e.g. delicate
upholstery, curtains, etc.
Medium power range
>
= For daily vacuuming of lightly soiled floors.
High power range
>
= For vacuuming durable floor coverings, hard floors
and heavy deposits of dirt.
Vacuu
m
ing
!
Caution
Floor nozzles are subject to a cer tain amount of
wear, depending on the type of hard floors you have
(e.g. rough, rustic tiles). You must therefore check
the underside of the floor nozzle at regular inter vals.
Worn undersides of floor nozzles may have sharp
edges that can damage delicate hard floors, such as
parquet or linoleum. The manufacturer does not ac-
cept any responsibility for damage caused by worn
floor nozzles.
Fig.
9
Set the adjustable floor nozzle:
Rugs and carpets =>
Hard floors/parquet =>
If you are vacuuming up relatively large par ticles, make
sure that you vacuum them up successively and careful-
ly to ensure that the vacuum channel of the floor nozzle
does not become blocked.
If necessar y, you should raise the nozzle in order to
better vacuum up the dir t par ticles.
Vacuu
m
ing with acce
ss
orie
s
Fig.
10*
Attach the nozzles to the suction pipe or handle as re -
quired:
a)
Crevice nozzle for vacuuming crevices and corners,
etc.
b)
Upholster y nozzle for vacuuming upholstered furni-
ture, cur tains, etc.
c)
Animal-hair nozzle
d)
Furniture brush
For cleaning window frames, cabinets, mouldings,
etc.
e)
Hard-floor nozzle for vacuuming hard floor coverings
(tiles, parquet flooring, etc.)
Drill du
s
t nozzle
Figure
11*
Fasten the drill dust nozzle onto the handle and
position it on the wall so that the drill hole opening
on the nozzle is placed directly over where the hole
is to be drilled.
Set the appliance to the lowest power level and
then switch it on.
* Dependent on model
The drill dust nozzle is held in the required position
by suction. Depending on the condition of the wall
to be drilled, you may need to adjust to a higher
power setting to ensure that the drill dust nozzle
remains in place.
During drilling, the fine dust is automatically vacu-
umed up.
Fig.
12
You can use the parking aid on the back of the vacuum
cleaner if you want to stop vacuuming for a shor t time.
After switching off the appliance, slide the hook on
the floor nozzle into the parking aid.
Fig.
13
When vacuuming stairs, the appliance must be positi-
oned at the bottom of the stairs. If it does not reach
far enough, the appliance can also be carried using the
carr ying handle.
After vacuu
m
ing
Fig.
14
Switch off the appliance.
Pull out the mains plug.
Briefly pull on the power cord and then let go. (The
power cord retracts automatically.)
Fig.
15*
Unlock the telescopic tube by moving the sliding
switch in the direction of the arrow, and slide one
tube into the other.
Fig.
16
To store the appliance, use the storage aid on the un-
derside.
a)
Prop up the appliance on the hose or dust-container
handle.
b)
Slide the hook on the floor nozzle into the storage
aid.
Di
s
a
ss
e
m
bly
Fig.
17
To remove the suction hose, press the two catches
together and pull out the hose from the appliance's
suction opening.
Fig.
18*
a)
Telescopic tube without accessor y connection:
To release the connection, turn the handle slightly
and pull it out of the telescopic tube.
b)
Telescopic tube with accessor y connection:
To release the connection, press the locking collar
on the telescopic tube and and pull out the handle.
Fig.
19*
a)
Nozzle without accessor y connection:
To release the connection, turn the telescopic tube
slightly and pull it out of the floor nozzle.
b)
Nozzle with accessor y connection:
To release the connection, press the locking collar
and pull the telescopic tube out of the floor nozzle.