In closed, poorly ventilated rooms, during the operation of the heater, a hard-to-breathe atmosphere may be
created and a lack of oxygen may form. If the oxygen concentration drops below 18%, the ODS (oxygen
level monitoring sensor) will work and turn off the heater. In this case, it is necessary to ventilate the room
before turning on the heating mode again.
ATTENTION!
Do not use the gas ceramic heater in rooms with a volume of less than 84 m
3
.
The minimum area of the vent must be at least 105 cm
2
.
The required air exchange is 10 m
3
/ h per 1 kW of heat output of the heater.
Control panel
Fig. 8
1. Gas adjustment knob
Used to supply gas to the burner and select the heating mode:
1st stage (
position),
2nd stage (
position)
3rd step (
position)
2. Piezo ignition button
Used to ignite the burner.
Turning on
1. Gently unscrew the gas cylinder valve.
2. Press and gently turn the gas adjustment knob on the control panel to the (
) position (Fig. 8).
Continue to hold down the gas adjustment knob for 20-30 seconds. Press the piezo ignition button several
times at a time until the gas burner lights up. Each time you press the piezo ignition button, you can hear a
loud click and see a spark on the piezo ignition electrode. Continue to hold the gas adjustment knob pressed
for 10-15 seconds from the moment the ignition torch ignites to activate the flame detector.
3. Leave the gas adjustment knob in this position for at least 5 minutes to permanently ignite the first heating
stage. The pilot (gas) burner and the central element of the ceramic burner will burn. This position
corresponds to a thermal power of 1.4 kW.
4. To change the heating level, slightly press the gas adjustment knob and smoothly turn it counterclockwise
until it locks in position
or
, which will correspond to a heating thermal power of 2.8 kW and
4.2 kW.
5. Do not leave the gas adjustment knob in the intermediate position between the fixed positions,
,
and
.
Turning off
1. Press the gas adjustment knob and turn it to the
position, while the gas (pilot) burner and the
central element of the ceramic burner will burn.
2. Turn the valve on the gas cylinder clockwise until it stops, the gas burner (pilot) and the central element of