Обогреватели Timberk T-GS4-G10 - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

IM2022
23
Beginning
1. Carefully remove the device from its packaging.
2. Ensure that there is no crumble of polystyrene foam or other debris remaining on the ceramic gas burner
and other parts of the appliance.
3. Install the paronite / rubber gasket inside the union nut, making sure that it is intact, and carefully screw
the nut onto the outlet of the previously prepared gas cylinder of the appropriate volume (gas cylinder is not
included in the delivery set, it is sold separately). Twisting the hose is strictly prohibited.
4. Slowly turn the gas regulator (cylinder valve) to make sure there is no gas leak. To do this: Lubricate all
connections with soapy water. In case of a gas leak, bubbles form in leaking places. If a gas l eak is detected,
turn off the gas supply and contact your dealer or the authorized service center.
ATTENTION!
It is necessary that all places of gas connections and pipes are absolutely tight to avoid the slightest gas
leak.
NEVER USE MATCHES, LIGHTERS, OR OTHER OPEN FLAME SOURCES TO CHECK FOR
LEAKS
. Use soapy water.
5. Install the gas cylinder in the intended place inside the device and secure it with the holder.
6. Move the heater to the intended place of work in compliance with the rules and precautions described in
the “Safeguards” section of this manual.
7. The device is ready to work.
ATTENTION!
It is forbidden to use a gas heater in apartments of multi-story buildings, bedrooms, bathrooms, basements
and in damp rooms.
• When switching on for the first time, it is recommended that you first turn on the heater outside in the open
air, after which it can be used indoors.
• The room in which the gas heater is used must have natural ventilation.
• Do not use the heater while sleeping.
• Do not use hoses and pressure reducers that are not certified, not recommended by the manufacturer or
with unsuitable characteristics for connecting the device.
• Always use only the type of gas specified by the manufacturer.
• Make sure that the gas cylinder is always in an upright position while the appliance is in operation. Using
the cylinder in any other position may lead to an emergency, device failure and serious damage to you and /
or your property.
• It is forbidden to move the heater or cover it with anything during its operation, and also after turning it off, if
it has not cooled down.
• The heater should be installed for operation so that it is placed with the front panel towards the center of
the room, while the distances to the walls or other objects on the sides and behind the device should be at
least 1 m.
ATTENTION!
Installation of the cylinder is prohibited:
- in living rooms and corridors;
- in basement and basement rooms and attics;
- in rooms located below and above: dining and trading rooms of catering establishments; classrooms, halls
of buildings; hospital wards; other similar facilities;
- in rooms without natural light;
- at emergency entrances;
- from the main building facades.
In case of fire:
- block access of gas by the locking device (valve);
- use a powder or carbon dioxide fire extinguisher or cover with blanket.
9.
OPERATION OF THE DEVICE
Ventilation
During the operation of the gas heater, the oxygen contained in the air is burned and carbon dioxide (CO
2
) is
released.
It is important to remember that the operation of a gas ceramic heater is permissible only in well -ventilated
areas. This allows to maintain the necessary concentration of oxygen in the air and remove products of
combustion.