6. Insert the upper portion of air ilter back into the unit
taking care that the left and right edges line up cor-
rectly and place ilter into position.
mAintenAnCe
If you plan to idle the unit for a long time, perform the
following:
1) Operate the fan for about half a day to dry the inside
of the unit.
2) Stop the air conditioner and disconnect power. Remove the batteries from
the remote controller.
3) The outdoor unit requires periodic maintenance and cleaning. Do not at-
tempt to do this yourself. Contact your dealer or service.
CheCks befoRe opeRAtion
• Check that the wiring is not broken off or disconnected.
• Check that the air ilter is installed.
• Check if the air outlet or inlet is blocked after the air conditioner has not been
used for a long time.
CAutions:
• Do not touch the metal parts of the unit when removing the ilter. Injuries can
occur when handling sharp metal edges.
• Do not use water to clean inside the air conditioner. Exposure to water can
destroy the insulation, leading to possible electric shock.
• When cleaning the unit, irst make sure that the power and circuit breaker are
turned off.
The following events may occur during normal operation.
1. Protection of the air conditioner.
• The compressor can’t restart for 3 minutes after it stops. Anti-cold air (Cooling
models only)
• The indoor or outdoor fan stop running when defrosting (Cooling models only).
Defrosting (Cooling only)
• The time to defrost may vary from 4 to 10 minutes according to the outdoor
temperature and the amount of frost buildup on the outdoor unit.
2. A white mist coming out from the indoor unit
A white mist may generate due to a large temperature difference between
air inlet and air outlet on COOL mode in an indoor environment that has a
high relative humidity.
3. Low noise of the air conditioner
• You may hear a low hissing sound when the compressor is running or has just
stopped running. This sound is the sound of the refrigerant lowing or coming
to a stop.
• You can also hear a low “squeak” sound when the compressor is running or
has just stopped running. This is caused by heat expansion and cold contrac-
tion of the plastic parts in the unit when the temperature is changing.
• A noise may be heard due to louver restoring to its original position when
power is irst turned on.
4. Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not been used for a
long time or during irst use of the unit.
opeRAtion tips
Содержание
- 3 Меры предосторожности
- 6 описание приБора
- 7 ручное управление
- 8 пульт дистанционноГо управления
- 10 управление приБороМ
- 11 ЭффеКтивность раБоты приБора
- 12 выБор направления воздуШноГо потоКа
- 13 основные принципы раБоты приБора
- 14 ЭКсплуатация
- 15 дополнительная инфорМация по раБоте приБора
- 17 устранение неполадоК
- 18 специфиКация