Rectifying faults
en
33
Errors
Cause
Troubleshooting
Display shows "Please refill
water tank" despite the fact
that the water tank is full.
New water filter was not
rinsed as per instructions.
1.
Rinse the water filter according to the
instructions.
"Insert water filter", Page 22
2.
Place the water filter into operation.
Air is in the water filter.
1.
Immerse the water filter in water with
the opening facing upwards until no
more air bubbles escape.
2.
Reinsert the filter.
"Insert water filter", Page 22
Water filter is old.
▶
Insert a new water filter.
Limescale deposits in the wa-
ter tank are blocking the sys-
tem.
1.
Clean the water tank thoroughly.
2.
Start the descaling programme.
"Using the descaling programme",
Display shows "Fill the bean
container with coffee beans."
despite the fact that the ban
container is full.
The grinder is not grinding
any coffee beans despite full
bean container.
Beans are too oily and are not
falling into the grinder.
▶
Gently tap the bean container.
▶
Change the coffee variety.
Do not use oily beans.
▶
Clean the empty bean container with
a damp cloth.
Display shows "Please clean
brewing unit, replace and
close door.".
Brewing unit is soiled.
▶
Clean the brewing unit.
"Cleaning brewing unit", Page 27
Mechanism of brewing unit is
stiff.
▶
Clean the brewing unit.
"Cleaning brewing unit", Page 27
Too much ground coffee in
the brewing unit.
▶
Use no more than 2 level measuring
spoons of ground coffee.
"Cleaning brewing unit", Page 27
Display shows "Voltage (V) in-
correct.".
Voltage in the house system is
incorrect.
▶
Only operate the appliance at 220 -
240 V.
Display shows "Please restart
appliance.".
Brewing unit is heavily soiled
or cannot be removed.
▶
Restart the appliance.
▶
Clean the brewing unit.
"Cleaning brewing unit", Page 27
Appliance has a fault.
1.
Pull out the mains plug and wait
5 seconds.
2.
Re-insert the mains plug.