Источники бесперебойного питания APC (BC650) - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

Back-UPS BC650-RSX761
7
Illuminates
Green
None
Power On
-The Back-UPS is supplying utility power to the
connected equipment.
Constant
tone
Overload Alarm
- The Back-UPS draws more voltage than
the utility voltage rating allows. Disconnect
non-essential equipment.
Constant
beeping
Overload Shutdown
- While operating on utility power the
Back-UPS experiences an overload condition.
Disconnect non-essential equipment, one device at a time
until the overload condition has been corrected.
The Back-UPS will shutdown if the overload condition is not
corrected.
Illuminates
Green
The LED is
not illuminated
during the
beeps.
4 beeps
once
every 30
seconds
On Battery
- The Back-UPS is supplying battery power to
the battery backup outlet.
Flashes Green
Rapid
beeps
once
every 1/2
second
Low Battery Indicator
- The Back-UPS is supplying battery
power to the battery backup outlet and the battery is near a
total discharge state.
The Back-UPS has 2 minutes of runtime remaining before
shutdown.
Constant
tone
Bad Battery Indicator
- The battery needs to be charged, or
is at the end of its service life.
The battery in this unit is not replaceable. Contact Schneider
Electric IT (SEIT).
Chirps
once
every 2
seconds
Charger Indicator
- The Back-UPS has detected an internal
error, and continues to provide power to the connected
equipment. Contact SEIT Technical Support.
Not
Illuminated
Constant
tone
On Battery Overload
- While operating on battery power the
connected equipment draws more voltage than the battery
capacity can provide.
Disconnect non-essential equipment, one device at a time
until the overload condition has been corrected.
If the problem persists, contact SEIT Technical Support.
Constant
tone
Internal Charger Error Detected
- The Back-UPS detects
an internal error and no longer provides power to connected
equipment. Contact SEIT Technical Support.
Constant
tone
Temperature Error Detected
- The Back-UPS has
overheated and has shut down.
Short
beeps
every 4
seconds
Low Battery Shutdown
- During On Battery operation the
battery is at a complete discharge state and the
Back-UPS stops providing output power. (Once utility power
is restored the Back-UPS will return to normal operation.)
Характеристики
Остались вопросы?Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)