The compressor runs for a long time.
→
The compressor switches to a low speed when little cold is
needed. Although the running time is increased as a result,
energy is saved.
u
This is normal in energy-saving models.
→
SuperCool is activated.
u
The compressor runs for longer in order to rapidly cool the
food. This is normal.
Excessive noise.
→
Speed-controlled* compressors may produce varying
running noise due to different speed steps.
u
The sound is normal.
A bubbling and gurgling noise.
→
This noise comes from the refrigerant flowing in the refriger-
ation circuit.
u
The sound is normal.
A quiet clicking noise.
→
The noise is produced whenever the refrigeration unit
(motor) automatically switches on or off.
u
The sound is normal.
A hum. It is briefly a little louder when the refrigeration
unit (the motor) switches on.
→
The refrigeration increases automatically when the Super-
Cool function is activated, fresh food has just been placed
in the appliance or the door has been left open for a while.
u
The sound is normal.
→
The ambient temperature is too high.
u
A low hum.
→
The sound is produced by air flow noise of the fan.
u
The sound is normal.
Vibratory noise.
→
The appliance is not standing firmly on the floor. As a result,
adjoining units or objects are set into vibration by the
running refrigeration unit.
u
Move bottles and containers apart.
Flow sound at the soft stop mechanism.*
→
The noise is produced when the door is opened and
closed.
u
The sound is normal.
The temperature display indicates:
F0
to
F5
.
→
There is a fault.
u
Contact the customer service (see Maintenance).
The temperature is not cold enough.
→
The door of the appliance is not properly closed.
u
Close the door of the appliance.
→
Insufficient ventilation.
u
Clear ventilation grilles.
→
The ambient temperature is too high.
u
→
The appliance was opened too frequently or for too long.
u
Wait until the appliance reaches the required temperature
itself. If not, contact the customer service. (see Mainte-
nance).
→
The temperature is incorrectly set.
u
Set to a colder temperature and check after 24 h.
→
The appliance is too close to a heat source.
u
Solution: (see Putting into operation).
→
The appliance was not inserted properly into the recess.
u
Check whether the appliance was inserted correctly and
the door closes properly.
The interior light is not on.
→
The appliance is not switched on.
u
Switch on the appliance.
→
The door was open longer than 15 min.
u
The interior light automatically switches off if the door has
been open for about 15 min.
→
The LED lighting is defective or the cover is damaged:
WARNING
Risk of injury due to electric shock!
Live parts are located under the cover.
u
Have the LED interior light changed or repaired only by the
customer service or by specialized personnel trained for the
purpose.
WARNING
Danger of injury due to laser radiation, class 1M.
u
Do not look inside when the cover is open.
8 Decommissioning
8.1 Switching off the appliance
u
Press On/Off button
Fig. 2 (4) for about 2 s.
w
The temperature display is dark.
8.2 Taking the appliance out of service
u
Empty the appliance.
u
Pull out the power plug.
u
Clean the appliance (see 6.2) .
u
Leave the door open to prevent odour.
9 Disposing of the appliance
The appliance contains some reusable materials
and should be disposed of properly - not simply
with unsorted household refuse. Appliances which
are no longer needed must be disposed of in a
professional and appropriate way, in accordance
with the current local regulations and laws.
When disposing of the appliance, ensure that the refrigeration
circuit is not damaged to prevent uncontrolled escape of the
refrigerant it contains (data on type plate) and oil.
u
Disable the appliance.
u
Pull out the plug.
u
Cut through the connecting cable.