19 

 
Filter saturation indicator 

The hood is equipped with a function that warns the user, at 
regular time intervals, when the filters are saturated and it is 
necessary to perform their maintenance.  

Grease filter saturation indicator:

 With the hood off 

(OFF)

 all 

suction speed (power) LEDs light up with steady light for 40 
seconds.  

Activated charcoal filter saturation indicator:

 With the hood off 

(OFF)

 all suction speed (power) LEDsflash for 40 seconds.  

 

Activation of the active charcoal filter saturation signal: 

normally, this function is disabled; to activate it, switch off the 
hood

 

(OFF)

 and simultaneously press buttons 

T3

 and 

T5

 for 

more than 3 seconds. LEDs 

L3

 and 

L5

 will start flashing.  

 

To disable repeat the operation: LEDs 

L3

 and 

L5

 light up with 

steady light. 

 

Resetting the filters’ saturation indicator: 

With the hood on 

(ON)

 press button 

T2

 for more than 2 seconds; 

all LEDs will light up briefly.  

Note:

 if necessary, repeat the operation in case both indicators 

(grease filter and activated charcoal filter) are active. 

 

Maintenance 

ATTENTION! 

Before performing any maintenance operation, 

isolate the hood from the electrical supply by switching off at 
the connector and removing the connector fuse.  
Or if the appliance has been connected through a plug and 
socket, then the plug must be removed from the socket. 

 

Cleaning 

The cooker hood should be cleaned regularly (at least with the 
same frequency with which you carry out maintenance of the 
fat filters) internally and externally.  Clean using the cloth 
dampened with neutral liquid detergent. Do not use abrasive 
products. 

DO NOT USE ALCOHOL!

 

WARNING: 

Failure to carry out the basic cleaning 

recommendations of the cooker hood and replacement of the 
filters may cause fire risks.  
Therefore, we recommend observing these instructions. 
The manufacturer declines all responsibility for any damage to 
the motor or any fire damage linked to inappropriate 
maintenance or failure to observe the above safety 
recommendations. 

 

Grease filter 

Fig. 9-16 
Traps cooking grease particles. 

 

This must be cleaned once a month (or when the filter 
saturation indication system – if envisaged on the model in 
possession – indicates this necessity)  using non aggressive 
detergents, either by hand or in the dishwasher, which must 
be set to a low temperature and a short cycle. 
When washed in a dishwasher, the grease filter may discolour 
slightly, but this does not affect its filtering capacity. 
To remove the grease filter, pull the spring release handle. 

 

Charcoal filter (filter version only) 

Fig. 15 
It absorbs unpleasant odours caused by cooking. 

The saturation of the charcoal filter occurs after more or less 
prolonged use, depending on the type of cooking and the 
regularity of cleaning of the grease filter. 
In any case it is necessary to replace the cartridge at least 
every four mounths (or when the filter saturation indication 
system – if envisaged on the model in possession – indicates 
this necessity).The charcoal filter may NOT be washed or 
regenerated. 

Circular carbon filter 

Apply one on each side as cover to both the shield grids of the 
motor impeller, then turn clockwise. 
For the disassembly, turn counter-clockwise. 

 

Replacing lamps 

Fig. 20 

Disconnect the appliance from the electricity. 

Warning! 

Prior to touching the light bulbs ensure they are 

cooled down. 
Replace the old light bulb with the one of the same type as 
specified in the feature label or near the light lamp on the 
hood. 

1.

  Using a flat head screwdriver or equivalent tool, carefully 

pry loose the light cover.   

2.

  Remove the damaged light and replace with a new 12 

Volt, 20 Watt (Maximum) halogen light made for a G-4 
base SUITABLE FOR USE IN OPEN LUMINAIRES.  
Follow package directions and do not touch new light 
with bare hands. 

3.

  Reinstall the light  cover. (it will snap shut). 

If the lights do not work, make sure that the lamps are fitted 
properly into their housings before you call for technical 
assistance. 
 
 

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Jetair Viki BL 60 A?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"