Use 

The hood is designed to be used either for exhausting or filter version. 
The models with no suction motor only operate in ducting mode, and must be connected to an external suction device (not supplied). 
The connecting instructions are supplied with the peripheral suction unit. 
 

    

Ducting version

 

In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connection ring located on 
top of the hood. 

Attention!

 The exhausting pipe is not supplied and must be purchased apart. 

Diameter of the exhausting pipe must be equal to that of the connection ring. 
In  the horizontal  runs  the  exhausting pipe  must  be  slightly  slanted  (about 10°)  and  directed upwards  to  vent  the  air  easily  from  the 
room to the outside. 

Attention!

 If the hood is supplied with active charcoal filter, then it must be removed. 

Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (connection flange). 
Using  the  tubes  and  discharge  holes  on  walls  with  smaller  dimensions  will  cause  a  diminution  of  the  suction  performance  and  a 
drastic increase in noise. 
Any responsibility in the matter is therefore declined. 

Use a duct of the minimum indispensible length. 

Use a duct with as few elbows as possible (maximum elbow angle: 90°). 

Avoid drastic changes in the duct cross-section. 

Use a duct with an as smooth as possible inside. 

The duct must be made of certified material. 

 

   

Filter version

 

One active charcoal filter is needed for this and can be obtained from your usual retailer. 
The filter removes the grease and smells from the extracted air before sending it back into the room through the upper outlet grid. 
 

Installation 

The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood 
must be not less than 50cm from electric cookers and 65cm from gas or mixed cookers. 
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to. 
 

  

Electrical connection

 

The  mains  power  supply  must  correspond  to  the  rating  indicated  on  the  plate  situated  inside  the  hood.  If  provided  with  a  plug 
connect  the  hood  to  a  socket  in  compliance  with  current  regulations  and  positioned  in an  accessible area,  after  installation.  If  it  not 
fitted with a plug (direct mains connection) or if the plug is not located in an accessible area, after installation,   apply a double pole 
switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over-current 
category III, in accordance with installation instructions. 

Warning!

 Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains 

cable is correctly assembled. 
The hood is provided with a special power cable ; if the cable is damaged, request a new one from Technical Service. 
 

Mounting 

Expansion  wall  plugs  are  provided  to  secure  the  hood  to  most  types  of  walls/ceilings.  However,  a  qualified  technician  must  verify 
suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the 
hood. Do not tile, grout or silicone this appliance to the wall. Surface mounting only. 
 

Operation 

Use the high suction speed in cases of concentrated kitchen vapours.  It  is  recommended that the cooker hood suction is switched 
on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating 
cooking. 
 
 
 
 
 

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Gorenje DK63MCLI?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"