ELECTRICAL CONNECTION 

  The  installation  of  this  appliance  and  the  connection  to  the  electrical  system  should  be 

entrusted only to a qualified electrician.  

  Protection against the parts under tension must be ensured after instalation 

  The  data  of  connection  necessary  are  on  the  stickers  place  on  the  hob  casing  near  the 

connection box. 

  The  connection  to  the  mains  must  be  made  using  an  earthed  plug  or  via  an  omnipolar 

circuit breaking device with a contact opening of at least 3 mm. 

  The  electrical  circuit  must  be  separated  from  the  network  by  adapted  devices,  for 

example: circuit breakers, fuses or contactors. 

  If  the  appliance  is  not  fitted  with  an  accessible  plug,  disconnecting  means  must  be 

incorporated in the fixed installation, in accordance with the installation regulations. 

  The inlet hose must be positioned so that it does not touch any of the hot parts of the hob 

or even. 

 

Caution! 
 

This appliance has only to be connected to a network 230 V~ 50/60 Hz 
Always connect the earth wire. 
Respect the connection diagram. 
The connection box is located underneath at the back of the hob casing. To open the cover, use 
a medium screwdriver. Place it in the slits and open the cover. 
 

( * ) calculated with the simultaneous factor following standard EN 60 335-2-6 

 
Setting up the configurations 
For the various kinds of connection, use the brass bridges which are in the box next the 
terminal. 

Monophase   230V~1P+N 

Put a bridge between terminal 1 and 2. 
Attach  the  earth  to the  terminate  “earth”,  the neutral  N  to  terminal  4,  the  Phase  L  to  one  of  the 
terminals 1 or 2. 

Biphase        400V~2P+N 

Attach  the  earth  to  the  terminate  “earth”,  the  neutral  N  to  terminal  4,  the  Phase  L1  to  the 
terminals 1 and the Phase L2 to the terminal 2. 

 

Caution! 

Frequent loosening and screwing of  the screws on the connection box risks 
damaging  the  efficiency  of  the  tightness  once  screwed.  It  is  therefore 
advisable to keep screwing and unscrewing to a minimum. 
Ensure that the cables are correctly inserted and tightly screwed down. 

We cannot be held responsible for any accident resulting from incorrect connection or 

which could arise from the use of an appliance which has not been earthed or has been 

equipped with a faulty earth connection 

 

Mains 

Connection 

Cable diameter 

Cable 

Protection calibre 

230V~  50/60Hz 

1 Phase   + N 

3 x 2,5 mm² 

H 05 VV - F 

H 05 RR - F 

25 A * 

400V~  50/60Hz 

2 Phases + N 

4 x 2.5 mm² 

H 05 VV - F 

H 05 RR - F 

 16 A * 

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Maunfeld MVCE45.3HL.SZ-BK?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"