Увлажнители Beurer LB 37 - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

17
Descaling
Descaling the ultrasound membrane
Hard water can cause limescale to build up in the device and, especially, on the ultrasound membrane. This forms
white deposits. Descale the device regularly.
• Drop some descaler onto the ultrasound membrane.
• Leave it to take effect for two to five minutes.
• Clean the ultrasound membrane using the cleaning brush.
• Rinse the base unit twice with clean, fresh water.
Cleaning inside the base unit
• Dip a damp, soft cloth briefly in descaling solution.
• Use the cloth to wipe the inside of the base unit.
• Carefully pour some clean, fresh water into the base unit.
• Empty the water from the base unit via the side edge.
• Repeat the process using clean, fresh water.
Descaling the water tank
• Half-fill the water tank with water.
• Add a small quantity of descaler.
• Tightly close the water tank using the screwed plug.
• Shake the water tank by rocking it back and forth several times.
• Empty the descaling solution completely.
• Repeat the process twice using clean, fresh water.
8. Spare parts
Tip!
If the water is hard, we recommend using the optional anti-limescale filter.
Anti-limescale filter (optional).
Order number 163.803. Please contact the national service address.
Note
• If the anti-limescale filter does not prevent limescale build-up, or if white deposits form on or in the device, the
anti-limescale filter should be replaced.
• The service life of the anti-limescale filter is around two to three months at most.
• If the device is not used for a relatively long time, the anti-limescale filter must be removed from the water tank
and dried out.
Fitting the anti-limescale filter
• Lift the water tank and rotate it.
• Open the screwed plug on the water tank.
• Screw the anti-limescale filter onto the screwed plug on the inside.
• Tightly close the water tank using the screwed plug.
9. What if there are problems?
Problem
Cause
Solution
No LED display
The mains cable is not plugged in. Connect the plug.
Red LED
The water level is too low; the wa-
ter tank is empty.
Fill the water tank.
No mist is produced
The LED display lights red .
Fill the water tank.
The LED display does not light up.
Характеристики
Остались вопросы?Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)