ENGLISH
•
Regularly check the power plug and power cord
integrity for damages.
•
Never use the unit if the power cord or the power
plug is damaged, if the unit works improperly or
after it was dropped.
•
Do not attempt to repair the unit. Do not disas-
semble the unit by yourself, if any malfunction is
detected or after it was dropped, unplug the unit
and apply to any authorized service center from the
contact address list given in the warranty certificate
and on the website www.vitek.ru.
•
Transport the unit in the original package only.
•
Keep the unit out of reach of children and disabled
persons.
THIS UNIT IS INTENDED FOR HOUSEHOLD USE ONLY.
ITS COMMERCIAL USAGE AND USAGE IN PRODUC-
TION AREAS AND WORK SPACES IS PROHIBITED.
BEFORE THE FIRST USE
After unit transportation or storage at low temper-
ature keep it for at least three hours at room tem-
perature before switching on.
– Unpack the unit, remove any stickers and pack-
age materials that can prevent the vacuum cleaner
operation.
– Check the unit for damages; do not use it in case
of damages.
– Before switching the unit on, make sure that your
home mains voltage corresponds to the unit oper-
ating voltage.
ASSEMBLING THE VACUUM CLEANER
Attaching and removing the flexible hose
•
Insert the flexible hose ending (8) into the air inlet
(10).
•
Insert the hose with a slight effort until locking.
•
If you need to remove the flexible hose, press the
lock (9) and detach the hose.
Attaching the telescopic pipe
and the attachments
•
Attach the telescopic extension pipe (4) to the han-
dle of the flexible hose (6).
•
Extend the lower part of the telescopic extension
pipe to the required length, having preliminary
pressed the clamp (3).
•
Choose the necessary attachment – universal floor/
carpet brush (1), furniture brush (29) or combined
attachment (30) – and attach it to the telescopic
extension pipe (4).
•
If necessary, you can attach the attachments (29,
30) directly to the flexible hose handle (6).
•
During the operation hold the unit by the handle (6).
USING THE BRUSH ATTACHMENTS
Universal brush with
the “FLOOR/CARPET” switch (1)
Set the switch (2) on the brush (1) to the required
position (depending on the type of the surface being
cleaned).
Combined attachment (30)
The combined attachment is intended not only
for cleaning radiators, crevices, corners or space
between cushions, but for collecting dust from fur-
niture surface as well, the pile on the brush (30)
prevents damage of polished furniture surface.
During the operation set the brush to the required
position.
Attachment (29)
Use the attachment (29) to clean the furniture uphol-
stery.
Dust bin (11)
The dust bin (11) is equipped with the cyclonic filter
which eliminates garbage and dust from the air, and
the foam (18) and HEPA (26) filters retain the finest dust
particles. The mesh filter (27) protects the HEPA filter
from garbage and large dust particles.
Note:
– provide that the foam (18) and HEPA filters (26) are
always clean, because the overall performance of
the vacuum cleaner depends on it.
USING THE VACUUM CLEANER
Safety measures
•
Do not use the vacuum cleaner near hot surfaces,
such as ashtrays and in places where inflammable
liquids are stored.
•
Take sharp objects away from the floor before
cleaning to prevent unit damage.
•
If the suction power of the vacuum cleaner
decreases rapidly while cleaning, switch it off
immediately and check the telescopic pipe (4)
and the flexible hose (7) for obstruction. Switch
the vacuum cleaner off, then unplug it, remove
the obstruction and only after that continue
cleaning.
USING THE VACUUM CLEANER
AT TENTION! You may switch the vacuum cleaner
on only with the dust bin (11) and the HEPA filter
(26) and the mesh filter (27) installed in the dust bin,
and with the outlet air filter (18) and the motor pro-
tection filter (21) installed. Always make sure that
the filters (18, 21, 26) and the mesh filter (27) are
installed properly.
•
Before using the unit, unwind the power cord (16)
to the required length and insert the power plug into
the mains socket.
•
The yellow mark on the power cord indicates the
maximum cord length. Do not unwind the power
cord further than the red mark.
•
Press the on/off button (12) to switch the vacuum
cleaner on.
•
During the operation you can control the suc-
tion power using the power control (14) and the
manual suction power control (5) on the flexible
hose handle (6). After room cleaning switch the
vacuum cleaner off by pressing the on/off button
(12) and unplug the unit.