There shall be no obstacles at a distance of 1 meter from two lateral sides, and at a distance of 2 meters from the 
front side of the charging base. At the base location area, there shall also be no mirrors and intensively reflecting 
surfaces within 15 cm heightwise from the floor. In case of presence of such surfaces, they shall be blanketed. 
Do not place the base against a window if exposure to direct solar radiation is possible. (Fig. 16) 
To start charging, move the power switch to the ON position, and put the vacuum cleaner on the base. Make sure 
that contact leads on the base align with contact leas on the device. 

The device status 

Indicator color 

Under charging 

Pink, glittering 

Low-charged battery 

Blue+pink, steady illumination 

Fully charged / under the cleanup mode 

Blue, steady illumination 

Turned off / under Sleep mode/ charged a long ago 

Dim 

Shows an error 

Red 

Do not leave the adapter unattended if energized after charging.  
Do not leave the charging base on the floor for long when not in operation. 

Attention! In is strictly prohibited to short-circuit the leads of the charging base! 
Prior  to  a  long-term  storage,  discharge  the  accumulator  to  the  half.  Do  not  keep  the  accumulator  under 
subzero ambient temperature. 
 
ACCUMULATOR REPLACEMENT (Fig. 17) 

1.

 

Turn off the device through the power switch. 

2.

 

Position the device so that its bottom panel faced upward. 

3.

 

Use  a cross  screwdriver  (beyond the delivery  set)  to  unscrew  the  screws  of  the battery  compartment  lid, and 
remove the lid by prying it up from the screws location side.  

4.

 

Take  out  the  depleted  accumulator  from  its  compartment,  and  disconnect  its  socket  by  pressing  the  power 
socket  latch  on  the  vacuum  cleaner,  and  pulling  out  the  accumulator  plug.  To  connect  a  new  accumulator, 
insert the accumulator plug into the power socket on the vacuum cleaner until the click. Carefully position the 
accumulator inside the compartment avoiding jamming connective wires. 

5.

 

 Put the battery compartment lid back on its place. Tighten the screws.  

CLEANING AND MAINTENANCE OF THE DEVICE 

1.

 

Prior to cleaning and maintenance, make sure to disconnect the device from the charger, and to disconnect the 
charger from a power network. 

2.

 

Do not dip the device or the charger into water or any liquids. 

3.

 

Do not use petrol, alcohol, and chemical solvents during cleaning the device. 

4.

 

Metal components of the device shall be wiped with a clean dry piece of cloth. 

5.

 

Plastic  components  of  the  device  shall  be  wiped  with  a  wet  wrung  piece  of  cloth.  No  water  droplets  are 
allowable. 

6.

 

The device shall be stored in a dry cool place. 

Pre-operation preparation of the wet cleaning container 

Attention!  If  the  wet  vacuuming  is  ceased  until  the  program  completion  (to  add  water)  the  vacuum  cleaner 
operation  resumption  can  start  from  cleaning  an  area  having  already  been  vacuumed.  Do  not  use  the  wet 
vacuuming when cleaning a carpet. 
Make always sure to timely add fresh water  into the container, and make always sure to empty the container 
after cleaning. Remove this container prior to charging the accumulator. 

Prior  to pouring  water,  follow  the  Figure  to position  at the container bottom  the  rag being  a  part  of  the  delivery 
set. (Fig. 7) 

 Pouring water. 

Open the intake orifice lid, carefully pour fresh water until it reaches the upper mark. Tightly secure the lid.  

CLEANING THE DUST BAG (Fig. 18) 
Each time after vacuuming: 

- Press the dust bag latch, and pull downward, 
- Take out the container by pulling it outward.  
- Check for foreign items clogging the channels. If any, remove them. 
- open the lid by pulling the latch downward, 
- Flip the container upside down and shake any debris out of it. 
- To extract and replace HEPA-filter you should release the latch on the dust bag lid. Empty the HEPA-filter by 

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Polaris PVCR 3200 IQ Home Aqua?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"