Пылесос Bosch BSGL 5ZOOO1 - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

47
* Dependent on model
Changing the filter
!
Please note:
Always switch off the appliance before
changing the filter.
Replacing the bag
Figure
If the dust bag change indicator in the lid is filled
completely when the floor tool is lifted from the floor
with the highest suction level selected, the dust bag
must be changed, even though it may not yet be full.
Even if the dust bag is not full, it may still need
changing, due to the type of dust which has been
vacuumed. First check that the nozzle, suction pipe
and flexible hose are not blocked, as this would also
lead to the dust bag change indicator being
triggered.
Figure Opening
the
lid
Open the lid by moving the locking lever in the
direction of the arrow.
Figure
a)
Seal the dust bag by pulling the sealing plate, and
remove the bag.
b)
Slide the new dust bag into the holder up to the stop.
!
Please note: the lid will only close if a dust bag has
been inserted.
Cleaning the motor protection filter
The motor protection filter should be cleaned regularly
by tapping out the dirt and rinsing.
Figure
Open the dust bag compartment lid.
Figure
Remove the motor protection filter from
the appliance in the direction of the arrow.
Disconnect the motor protection filter from the Bionic
filter.*
Clean the motor protection filter by tapping out the
dirt.
If it is very dirty, the motor protection filter should be
rinsed. The filter must then be left to dry for at least
24 hours.
!
Please note:
the Bionic filter must not come into
contact with water, as this will adversely affect the
correct operation of the filter.
After cleaning, place the Bionic filter onto the motor
protection filter as necessary and push both filters
into the appliance.
Close the dust bag compartment lid.
Replacing the Bionic filter
If your appliance is equipped with a Bionic filter, it
should be replaced once it begins to lose its effect
(after approx. 1 year).
Figure
Open the dust bag compartment lid.
Figure
Remove the motor protection filter together with the
Bionic filter from the appliance.
Remove the old Bionic filter from the motor
protection filter and dispose of it.
21
22
23*
21
24*
21
20*
Place the Bionic filter onto the motor protection filter.
Push the filters into the appliance and close the dust
bag compartment lid.
The motor protection filter must also be inserted into
the appliance if you no longer wish to use the Bionic
filter
Replacing the exhaust filter
Replacing the micro-hygiene filter
This should be replaced with every replacement filter pack.
Figure
Open the dust bag compartment lid.
Figure
Release the filter holder by turning the locking lever
in the direction of the arrow.
Remove the micro-hygiene filter. Insert the new
micro-hygiene filter into the appliance.
Insert the filter holder in the appliance and lock it in
place.
Cleaning the Hepa* exhaust filter
The Hepa* filter is designed so that it does not need to be
replaced, provided the appliance is used as intended in the
household.
To ensure that the vacuum cleaner is working at its optimum
power level, the Hepa* filter should be rinsed out after one
year. The filtering action of the filter remains intact, even if the
filter surface becomes discoloured.
Figure
Open the dust bag compartment lid.
Unlock the Hepa* filter by moving the locking tab in the
direction of the arrow, and remove it from the appliance.
Tap out the filter unit and rinse it under running water.
Alternatively, the unit can be cleaned in a washing machine
at max. 30 °C using a gentle programme and the lowest spin
speed.
TIP: To protect other laundry items, put the filter unit into a
laundry bag.
Once the Hepa* filter has dried completely (at least 24
hours), insert it back into the appliance and lock it in place.
Close the rear flap.
After vacuuming fine dust particles (e.g. gypsum, cement, etc.),
clean the motor protection filter by tapping it out or, if
necessary, replace the motor protection filter and exhaust
filter.
Care
Always switch off the vacuum cleaner and disconnect
it from the mains before cleaning the vacuum cleaner.
The vacuum cleaner and plastic accessories can be
cleaned with a commercial plastic cleaner.
!
Do not use abrasive agents, glass or all-purpose
cleaning products. Never immerse the vacuum
cleaner in water.
If necessary, the dust compartment can be cleaned
with a second vacuum cleaner or simply wiped with
a dry cloth or dusting brush.
Subject to technical modifications.
25
21
26*