Парогенераторы Polti XM80C La Vaporella - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

15. TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
If
water
comes
out from the Iron
soleplate
instead
of steam
The correct temperature
was not reached.
Check that the indicator light is con-
stant blue, indicating that Polti La Va-
porella has reached the correct tem-
perature.
First steam release.
Release onto a cloth until steam comes
out from the holes on the solepate.
Steam does not
come out from the
Iron soleplate
No power/ dial set on
or
on the SILK program.
Ensure that the appliance is connected
to the power supply and that the dial is
set on another program other than
SILK.
only for model XT90C
No power/ dial set on
program.
only for model XT90C
Ensure that the appliance is connected
to the power supply and that the dial is
set on another program other than
.
Water tank is empty.
Fill the tank as described in section 10.
Little
steam
comes from the
Iron soleplate.
The steam is dry, so is
barely visible, but is pre-
sent and effective
This is normal especially in particular
environmental conditions.
The
appliance
does not turn on.
Dial set on
.
Turn the dial to the desired program.
No power.
Check that the appliance has been
connected to the the mains, as indi-
cated in section 1.
The water tank is
full,
but
steam
doesn't come out.
The iron has not reset the
water level.
Keep the steam button pressed down
for at least one second, as described in
section 10.
Water tank is not inserted
correctly.
Correctly insert the water tank.
Some water drops
are present on the
fabric.
The ironing board cover is
saturated with water as it
is not suited to the power
of an iron with a high-pres-
sure boiler.
Check that the board is suitable (board
with grille that prevents condensation).
The
automatic
shut-down
does
not work after 10
minutes of non-
use.
The STEAM PULSE func-
tion or TURBO function is
operational.
Deactivate
the
STEAM PULSE
and
TURBO function.
Should the problems persist, contact an Authorised Polti Service Centre (see
www.polti.co.uk for the up-to-date list) or Customer Services.
E
N
G
L
IS
H
| 29 |
Характеристики
Остались вопросы?Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)