Prior to first use
1)
Place the device upright on a solid,
level, and moisture resistant surface.
Keep the device away from walls.
2) To ensure optimum performance of
the device, please ensure that the air
inlets and air outlets are not covered.
3) Inspect the power cord to ensure
that it is not damaged.
4) Remove the housing cover from the
device (1.1). Pull the water tank upward
to remove it from the housing (1.2).
5) Pull the tub out of the housing and
remove the cleaning drum (3.1). Remove
the packaging and insert the drum and
tub back into the device.
6) Place the water tank, with the screw
cap facing up, on a level surface. Open
the screw cap (C) on the bottom of the
tank. Fill the water tank with fresh water.
Then use the screw cap to close the
water tank. Ensure that the water tank is
tightly closed.
7) Insert the water tank back into the
housing and ensure that the water tank
is inserted securely and correctly.
www.cooperandhunter.com
•
Switching on and off.
Push the ON/OFF switch (
I
) to switch the device on or off. When
switched on, the display (
H
) will show the current relative ambient air
humidity. (At first use the device starts at medium humidification
level).
•
Setting the operating time.
Push the key (
J
) to set the desired operating time. Select between
1 and 12 hours operating time or CO for continuous operation of
the device:
CO (standard) -01-02-03-04-05-06-07-08-09-10-11-12
•
Changing the fan speed.
Push the key (
K
) to select the fan speed and thus the desired
intensity of humidity output:
Low – Medium – High
•
Setting the target humidity.
Set the desired humidity in % by pushing the key (
L
). The value will
be shown on the display while you set the desired humidity. After a
few seconds, the display automatically switches to the currently
measured value. We recommend a relative air humidity between 40
% and 60 %. The device can be set between 40 % to 80 %. The
device shuts off as soon as the pre-set air humidity is exceeded.
The device does not shut off while in continuous operation (CO).
•
Resetting the filter’s operating time meter
The combination filter should be replaced after 1000 operating
hours. To reset the operating time meter, push and hold key (
M
) for
5 seconds until a signal sounds. Replacement of the filter is
described in Chapter 7.
1.1
1.2
3.1
8) Place the housing cover back
on the housing.
9) Remove the filter cover on the
side of the device (2.1).
2
.1
2.2
10) Remove the packaging from the filter and insert the filter into the filter cover.
(2.2) Ensure that the white side of the filter faces in (towards the device).
11) Insert the filter unit back into the device. Ensure that the filter unit is inserted
correctly.
12) Connect the power cord to a power outlet.
Daily use and operation