Обогреватели Ballu-Biemmedue GP 10M C - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

EN
16
Warning
The  dimensions  of  the  gas  cylinder  must  be  based  on 
the required gas flow rate and supply pressure. 
The  supply  pressure  to  the  pressure  regulator  must 
always be greater than 2 bar. 
The  heater  is  supplied  complete  with  gas  hose  (a)  and  pressure 
reducer  (c)  with  fittings  (d)  for  connection  to  different  types  of 
cylinders.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Depending  on  the  country  of  destination,  the  heater  may  be 
supplied with various types of gas pressure regulator.
Warning
The  installer  is  responsible  for  guaranteeing  that  the 
correct  fitting  is  used  for  the  connection  to  the  gas 
cylinder. 
Always  tighten  the  cylinder  fitting  first,  and  then  the 
pressure regulator, which has a swivel fitting. 
 
TYPE I 
•  pressure  regulator  with  G5  fitting  for  AT-BG-CY-DK-DE-EE-LT-
LV-MK-MT-RO-TR-NL.
• G5/G2 fitting, with G2 fitting for G2 for BE-CZ-ES-FR-HR-HU-
LU-PL-PT-SI-SK.
•  G5/G1 fitting, with G1 fitting for IT-GR 
•  G5/G7 fitting, with G7 fitting for FI - IE – GB (only if requested) 
•  G5/G9 fitting, with G9 fitting for SE – NO (only if requested) 
•  G5/G5R fitting, with G5R fitting for CH – NL (only if requested) 
•  seal for NL, to install on G5 pressure regulator for NL. 
TYPE II 
•  pressure regulator with G7 fitting for FI - IE - GB. 
TYPE III 
•  pressure regulator with G9 fitting for SE - NO. 
 
Warning
The  seal  of  the  fittings  must  be  checked  by  pouring 
liquid  soap  on  them:  the  appearance  of  bubbles 
indicates a possible gas leak. 
Warning
Propane  and  buthane  are  heavier  than  air,  therefore 
any gas leakage can cause gas stagnation on the floor 
or in any underlying room.
A safety valve (b) may be ordered for protection in case of a
broken gas hose. Installation of this valve is mandatory if required by 
local installation laws and regulations. 
The gas cylinder must be changed and replaced in an open room,
away from sources of heat and open flame, taking care to check that 
the instructions in this paragraph are followed. 
 
Warning 
Always  make  sure  that  the  seal  (if  required  by  the 
fitting)  is  present  between  the  reducer  and  the 
cylinder. 
Warning
Make  sure  that  the  gas  hose  has  been  tightened 
without  being  twisted:  any  stress  from  twisting  can 
seriously damage the hose.
OPERATING INSTRUCTIONS
Warning
Before  switching  on  the  heater,  check  that  the  power 
supply  specifications  are  the  same  as  those  stated  on 
the identification plate. 
START
To start the space heater: 
•   Set the pressure regulator to maximum pressure  
•  Slowly open the gas cylinder valve the gas bottle. 
 
Warning
In  case  of  a  gas  leak,  close  the  gas  stopcock 
immediately,  close  the  gas  cylinder  valve,  switch  off 
the  heater,  remove  the  plug  from  the  electrical  panel, 
and call customer service to find the origin of the leak. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
•   Turn on the disconnecting switch on the main electrical panel; 
•   Move the switch to position (I); fan starts; 
•   Press  the  gas  valve  button  and  simultaneously  press  the 
piezoigniter once or twice until the flame lights up.
• Keep the gas valve button pressed for 15 / 20 seconds until the
thermocouple is sufficiently heated: when button 13 is released, 
the flame stays on. 
If the heater still does not function, see
TROUBLESHOOTING” to
identify the cause of the malfunction.
 
STOP 
To stop the heater, turn the switch to position “0”: the flame goes
out and the fan motor stops.
Lastly, close the gas supply stopcock and turn off the isolation
switch.
Warning
Wait  at  least  2  minutes  before  restarting  the  heater  to 
allow the thermocouple to cool completely. 
 
 
Warning 
If  the  heater  is  not  used  continuously,  stop  it  by  first 
closing  the  gas  supply  stopcock  and  then  switch  it  off 
by  pressing  button  (9)  or  by  turning  down  the 
thermostat:  this  allows  the  gas  in  the  gas  tube  to  be 
fully  used  and  avoids  any  future  leak  when  removing 
the gas tube. 

 
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 