Data Hold mode
Press the"
HOLD
" button to enter Data Hold mode, the present reading will be held
on the display and the symbol „
H
”
will appear on the display as an indication. To
exit Data Hold mode, press this button again.
Note:
If you turn the rotary switch to other switch position when the meter is in Data Hold
mode, the meter will not exit Data Hold mode (but the position of the decimal point
may change). In this condition, you can press the
"
HOLD
" button to exit Data Hold
mode.
Measuring DC Voltage
1.
Connect the black test lead to the
"
COM
" terminal and the red test lead to the
"
V
"
terminal.
2.
Set the rotary switch in desired
range position.
3.
If the magnitude of the voltage to be measured is not known beforehand, set the
rotary switch in the highest range position first and then reduce it range by range
until satisfactory resolution is obtained.
4.
Connect the test leads across the source or circuit to be tested.
5.
Read the reading on the display. The polarity of the red test lead connection will be
indicated as well.
Note:
To avoid electric shock to you or damage to the meter, do not apply a voltage higher
than 300V between the terminals.
Measuring AC Voltage
1.
Connect the black test lead to the
"
COM
" terminal and the red test lead to the
"
V
"
terminal.
2.
Set the rotary switch in desir
ed
range position.
If the magnitude of the voltage to
be measured is not known beforehand, set the rotary switch in the highest range
position first and then reduce it range by range until satisfactory resolution is
obtained.
3.
Connect the test leads across the source or circuit to be tested.
4.
Read the reading on the display.
Note:
To avoid electric shock to you or damage to the meter, do not apply a voltage higher
than 300V between the terminals.
Measuring DC Current
1.
Connect the black test lead to the
"
COM
"
terminal. Connect the red test lead to the
"
mA/Ω/BATT
"
terminal if the current to be measured is less than 200mA. If the
current is between 200mA and 10A, connect the red test lead to the"
10A"
terminal
instead.
2.
Set the rotary switch in desired
range position.
Note:
If the red test lead is connected to the"
10A
" terminal, the rotary switch must
be set in the 10A range position in the
area.
If the red test lead is connected to
the "
mA/Ω/BATT
"
terminal, never set the range switch in the 10A range position.