Safety Principles for Installing Air Conditioner
Requirements For Installation Position
• Fire prevention device shall be prepared before installation.
• Keep installing site ventilated.(open the door and window)
• Ignition source,smoking and calling is not allowed to exist in area where R32 refrigerant rocated.
• Anti-static precautions in necessary for installing air conditioner, e.g. wear pure cotton clothes and gloves.
• Keep leak detector in working state during the installation.
• If R32 refrigerant leakage occurs during tfle installation, you shall immediately detect the concentration in indoor
environment until it reaches a safe level. If refrigerant leakage affects the performance of the air conditioner,
please immediately stop the operation, and the air conditioner must be vacuumed firstly and be returned to the
maintenance station for processing.
• Keep electric appliance, power switch, plug, socket, high temperature heat source and high static away from the
area underneath sidelines of the indoor unit.
• The air conditioner shall be installed in an accessible location to installation and maintenance, without obstacles
that may block air inlets or outlets of indoor/outdoor units, and shall keep away from heat source inflammable or
explosive conditions.
• When installing or repairing the air conditioner and the connecting line is not long enough, the entire
connecting line shall be replaced with the connecting line of the original specification; extension is not allowed.
• Use new connection pipe, unless re-flaring the pipe.
• Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases.
• Avoid places subject to strong artificial electric/magnetic fields.
• Avoid places subject to noise and resonance.
• Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine or h1gli temperature
heat sources).
• Avoid places within the reach of cnildren.
• Shorten the connection between the indoor and outdoor units.
• Select where it is easy to perform service and repair and where the ventilation good.
• The outdoor unit shalrnot be installed in any way that could occupy an aisle, stairway, exit, fire escape, catwalk or
any other public area.
• The outdoor unit shall be installed as far as possible from the doors and windows of the neighbors as well as the
green plants.
Installation environment inspection
• Check nameRlate of outdoor unit to make sure whether the refrigerant is R32.
• Check the floor space of the room. The space shall not be less than usable space(sm2 ) in the specification.The
outdoor unit shall be installed at a well-ventilated place.
• Check the surrounding environment of installation site: R32 shall not be installed in the enclosed reserved space
of a building.
• When using electric drill to make holes in the wall, check first whether there is pre-buried pipeline for water,
electricity and gas.
• It is suggested to use the reserved hole in the roof of tfle walr
Requirements of the mounting structure
• The mounting rack must meet the relevant national or industrial standards in terms of strength with welding and
connection areas rustproofed.
• The mounting rack and its load carry surface shall be able to withstand 4 times or above the weight of the unit,
or 200kg, whichever is heavier.
• The mounting rack of the outdoor unit shall be fastened with expansion bolt.
• Ensure the secure installation regardless of what type of wall on which it is installed, to prevent potential
dropping that could hurt people.
Содержание
- 3 ВНИМАНИЕ
- 5 ПРЕДУПРЕЖДЕНИЯ ПО ИСПОЛЬЗОВАНИЮ; Состояния при которых система будет работать неисправно
- 6 Примечания по обогреву
- 7 НАИМЕНОВАНИЯ ДЕТАЛЕЙ; Внутренний блок
- 8 Очистите панель; ЧИСТКА И УХОД
- 9 Уход после использования; ПОИСК НЕИСПРАВНОСТЕЙ
- 10 ЗАМЕЧАНИЯ ПО УСТАНОВКЕ; Осмотр при распаковке
- 11 Правила безопасности при установке кондиционера
- 12 Требования к работе на высоте
- 13 Другое; УСТАНОВКА ВНУТРЕННЕГО БЛОКА; Габаритный чертеж установки внутреннего блока
- 14 Монтажная пластина
- 15 Соединение сливной трубы; Крепление внутреннего блока
- 16 Схема подключения
- 17 УСТАНОВКА НАРУЖНОГО БЛОКА; Габаритный чертеж установки наружного блока
- 18 Подключение проводки
- 19 Проверка после установки
- 20 Пробная эксплуатация; ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ; Осмотр площадки
- 21 Рабочие процедуры
- 22 Осмотр кабеля; Удаление воздуха; Порядок заправки хладагентов
- 23 Утилизация и восстановление
- 25 Описание кнопок
- 28 Использование
Характеристики
Остались вопросы?Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)