9
English
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Single split outdoor unit
CU-E7RKD, CU-E9RKD, CU-E12RKD,
CU-E15RKD, CU-E18RKD, CU-E24RKD,
CU-E28RKD
Indoor
Outdoor
DBT WBT DBT WBT
COOL
Max. 32
23
43
26
Min. 16
11
10
-
HEAT
Max. 30
-
24
18
Min. 16
-
-10
-
°C (temperature)
Multi split outdoor unit
CU-2E15PBD, CU-2E18PBD, CU-4E27PBD,
CU-5E34PBD, U-3E18JBE, U-4E23JBE
Indoor
Outdoor
DBT WBT DBT WBT
COOL
Max. 32
23
46
26
Min. 16
11
-10
-
HEAT
Max. 30
-
24
18
Min. 16
-
-15
-16
°C (temperature)
To
learn more...
Sunlight Sensor operation
Set
temperature
HEAT
COOL/DRY
+1 °C
-1 °C
-1 °C
ECONAVI
; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
• Based on area activeness horizontal air
fl
ow direction will adjust either
fi
x
at predetermined position or swing left/right periodically.
• The human activity sensor performance is in
fl
uenced by indoor unit
location, movement speed, temperature range, etc.
120º
7m
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidi
fi
er from the sensor’s detection
area. They may cause sensor malfunction.